Isoseparation curves: a mechanism for optimizing off-axis dose homogeneity of intact breast irradiation.

T A Buchholz, S Bilton, E Gurgoze, E A Strom, M D McNeese, W S Bice, B R Prestidge
{"title":"Isoseparation curves: a mechanism for optimizing off-axis dose homogeneity of intact breast irradiation.","authors":"T A Buchholz,&nbsp;S Bilton,&nbsp;E Gurgoze,&nbsp;E A Strom,&nbsp;M D McNeese,&nbsp;W S Bice,&nbsp;B R Prestidge","doi":"10.1002/(SICI)1520-6823(1998)6:4<191::AID-ROI7>3.0.CO;2-T","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this paper is to determine whether using off-axis isoseparation curves to optimize the collimator rotation angle improves dose homogeneity. Eleven intact breast irradiation patients underwent computerized tomography (CT) treatment planning with 1 cm abutting slices. Central plane treatment planning, using 6 MV photons, tissue inhomogeneity corrections, and isocentric opposed tangent treatment fields, was performed. Collimators were rotated to match chest wall slope through the use of a beam's-eye-view setting. Patient separations were measured from the apex of the breast to the posterior field border on each axial CT slice. Sagittal-plane isoseparation curves were constructed from these measurements. Using these curves, the collimator rotation that minimized off-axis separation differences was determined. A comparison of off-axis dose inhomogeneity was performed for patients with a > or =10 degrees difference between this optimized collimator angle and the angle determined by chest wall slope. These comparative treatment plans differed only with respect to collimator angle rotation. The mean optimal collimator rotation angle differed significantly from the mean rotation angle which matched the chest wall slope (5.4 degrees vs. 11 degrees, respectively, P < 0.001). Four of the 11 patients had rotation angle differences of 10 degrees. In these patients, the optimization of collimator angle reduced the percentage of breast volume to \"that\" received > or =110% of the prescribed dose. For the patient with the largest breast size to the patient with the smallest breast size the decreases were, respectively, 5% (15% to 10%), 3% (24% to 21%), 1% (4% to 3%), and 1% (0.9% to 0%). The mean reduction in dose inhomogeneity was greatest in the inferior breast quadrants. At 6 cm and 4 cm off axis, the mean reductions in the percentages of the breast tissue to \"that\" received 110% of the prescribed dose were respectively 15.1% and 5.3 %. Optimizing the collimator angle through the use of isoseparation curves decreases dose inhomogeneity. The greatest improvements are in the inferior quadrants of the intact breast. The improved dose homogeneity may have clinical relevance in the treatment of patients with large breast sizes.</p>","PeriodicalId":20894,"journal":{"name":"Radiation oncology investigations","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1520-6823(1998)6:4<191::AID-ROI7>3.0.CO;2-T","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation oncology investigations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/(SICI)1520-6823(1998)6:4<191::AID-ROI7>3.0.CO;2-T","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

The purpose of this paper is to determine whether using off-axis isoseparation curves to optimize the collimator rotation angle improves dose homogeneity. Eleven intact breast irradiation patients underwent computerized tomography (CT) treatment planning with 1 cm abutting slices. Central plane treatment planning, using 6 MV photons, tissue inhomogeneity corrections, and isocentric opposed tangent treatment fields, was performed. Collimators were rotated to match chest wall slope through the use of a beam's-eye-view setting. Patient separations were measured from the apex of the breast to the posterior field border on each axial CT slice. Sagittal-plane isoseparation curves were constructed from these measurements. Using these curves, the collimator rotation that minimized off-axis separation differences was determined. A comparison of off-axis dose inhomogeneity was performed for patients with a > or =10 degrees difference between this optimized collimator angle and the angle determined by chest wall slope. These comparative treatment plans differed only with respect to collimator angle rotation. The mean optimal collimator rotation angle differed significantly from the mean rotation angle which matched the chest wall slope (5.4 degrees vs. 11 degrees, respectively, P < 0.001). Four of the 11 patients had rotation angle differences of 10 degrees. In these patients, the optimization of collimator angle reduced the percentage of breast volume to "that" received > or =110% of the prescribed dose. For the patient with the largest breast size to the patient with the smallest breast size the decreases were, respectively, 5% (15% to 10%), 3% (24% to 21%), 1% (4% to 3%), and 1% (0.9% to 0%). The mean reduction in dose inhomogeneity was greatest in the inferior breast quadrants. At 6 cm and 4 cm off axis, the mean reductions in the percentages of the breast tissue to "that" received 110% of the prescribed dose were respectively 15.1% and 5.3 %. Optimizing the collimator angle through the use of isoseparation curves decreases dose inhomogeneity. The greatest improvements are in the inferior quadrants of the intact breast. The improved dose homogeneity may have clinical relevance in the treatment of patients with large breast sizes.

等分离曲线:一种优化完整乳腺辐照离轴剂量均匀性的机制。
本文的目的是确定使用离轴等分离曲线来优化准直器旋转角度是否能改善剂量均匀性。11例完整乳房放疗患者行CT治疗计划,相邻切片1 cm。使用6 MV光子、组织不均匀性校正和等心对切治疗场进行中央平面治疗计划。通过使用光束视角设置旋转准直器以匹配胸壁斜率。在每个轴向CT切片上测量患者从乳房顶点到后野边界的距离。根据这些测量结果构建了矢状面等分离曲线。利用这些曲线,确定了使离轴分离差最小的准直器旋转。对优选准直器角度与胸壁斜率确定的角度相差>或=10度的患者进行离轴剂量不均匀性比较。这些比较治疗方案仅在准直器角度旋转方面有所不同。平均最佳准直器旋转角度与匹配胸壁斜度的平均旋转角度差异显著(分别为5.4度和11度,P < 0.001)。11例患者中有4例旋转角度差达10度。在这些患者中,准直角度的优化将乳房体积百分比降低到“接受”>或=规定剂量的110%。乳房尺寸最大的患者与乳房尺寸最小的患者的差异分别为5%(15%至10%)、3%(24%至21%)、1%(4%至3%)和1%(0.9%至0%)。剂量不均匀性的平均减少在乳房下象限最大。在离轴6厘米和4厘米处,接受110%处方剂量的乳腺组织百分比的平均减少分别为15.1%和5.3%。利用等分离曲线优化准直角,降低了剂量不均匀性。最大的改善是在完整乳房的下象限。改善的剂量均匀性可能对治疗大乳房患者具有临床意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信