{"title":"Studies of prosody perception by cochlear implant patients.","authors":"L M Richardson,&nbsp;P A Busby,&nbsp;P J Blamey,&nbsp;G M Clark","doi":"10.3109/00206099809072977","DOIUrl":null,"url":null,"abstract":"<p><p>Prosodic information is conveyed to normally-hearing listeners by variations in acoustic fundamental frequency, amplitude envelope, and duration of speech segments. This study measured cochlear implant patients' sensitivity to these parameters in electrically coded speech. The psychophysical discrimination of electric parameters used to code prosodic information, were examined, together with prosody perception using speech processing strategies which modified the contributions of these parameters. Patients were implanted with the Cochlear Limited prosthesis and used the MPEAK speech processing strategy. In the psychophysical studies, difference limens were measured for steady-state and time-varying stimuli, of different pulse rates and pulse durations, over a series of different stimulus durations. These limens were obtained using an adaptive procedure which converged on the 50 per cent correct point. In the prosody perception studies, performance was measured for the MPEAK strategy and for strategies which modified the contributions of pulse rate and pulse duration. Data were collected for five tests of prosodic contrasts. Difference limens for steady-state pulse rates were larger at higher rates (17 per cent at 400 pulses/s) than at lower rates (6 per cent at 100 pulses/s). For some patients, limens for the time-varying pulse rates were larger than those for the steady-state pulse rates while for the other patients, the limens were similar. Difference limens for pulse duration were 0.3 dB, corresponding to 4 per cent of the dynamic range, for steady-state stimuli and doubled in size for the time-varying stimuli. Prosody perception performance was generally poorer for the modified strategies than for the MPEAK strategy, suggesting that the removal of information coded by pulse rate and pulse duration reduced the perception of prosodic contrasts.</p>","PeriodicalId":75571,"journal":{"name":"Audiology : official organ of the International Society of Audiology","volume":"37 4","pages":"231-45"},"PeriodicalIF":0.0000,"publicationDate":"1998-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/00206099809072977","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology : official organ of the International Society of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/00206099809072977","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Prosodic information is conveyed to normally-hearing listeners by variations in acoustic fundamental frequency, amplitude envelope, and duration of speech segments. This study measured cochlear implant patients' sensitivity to these parameters in electrically coded speech. The psychophysical discrimination of electric parameters used to code prosodic information, were examined, together with prosody perception using speech processing strategies which modified the contributions of these parameters. Patients were implanted with the Cochlear Limited prosthesis and used the MPEAK speech processing strategy. In the psychophysical studies, difference limens were measured for steady-state and time-varying stimuli, of different pulse rates and pulse durations, over a series of different stimulus durations. These limens were obtained using an adaptive procedure which converged on the 50 per cent correct point. In the prosody perception studies, performance was measured for the MPEAK strategy and for strategies which modified the contributions of pulse rate and pulse duration. Data were collected for five tests of prosodic contrasts. Difference limens for steady-state pulse rates were larger at higher rates (17 per cent at 400 pulses/s) than at lower rates (6 per cent at 100 pulses/s). For some patients, limens for the time-varying pulse rates were larger than those for the steady-state pulse rates while for the other patients, the limens were similar. Difference limens for pulse duration were 0.3 dB, corresponding to 4 per cent of the dynamic range, for steady-state stimuli and doubled in size for the time-varying stimuli. Prosody perception performance was generally poorer for the modified strategies than for the MPEAK strategy, suggesting that the removal of information coded by pulse rate and pulse duration reduced the perception of prosodic contrasts.

人工耳蜗患者韵律感知的研究。
韵律信息通过声音基频、振幅包络和语音片段持续时间的变化传递给听力正常的听者。这项研究测量了人工耳蜗患者在电编码语言中对这些参数的敏感性。研究了用于编码韵律信息的电参数的心理物理辨别,以及使用修改这些参数贡献的语音处理策略的韵律感知。患者被植入人工耳蜗,并使用MPEAK语音处理策略。在心理物理研究中,在一系列不同的刺激持续时间下,测量了不同脉冲速率和脉冲持续时间的稳态和时变刺激的差异阈值。这些元素是使用自适应程序获得的,该程序收敛于50%的正确率点。在韵律感知研究中,测量了MPEAK策略和修改脉搏率和脉搏持续时间贡献的策略的表现。收集了五项韵律对比测试的数据。稳态脉冲速率的差值在较高速率下(400脉冲/秒时为17%)比在较低速率下(100脉冲/秒时为6%)更大。对于一些患者,时变脉率的阈值大于稳态脉率的阈值,而对于其他患者,阈值相似。对于稳态刺激,脉冲持续时间的差值为0.3 dB,相当于动态范围的4%,而对于时变刺激,脉冲持续时间的差值则增加了一倍。改进策略的韵律感知表现通常比MPEAK策略差,这表明去除脉冲速率和脉冲持续时间编码的信息降低了韵律对比的感知。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信