{"title":"Single-sweep cortical somatosensory evoked potentials: N20 and evoked bursts in sevoflurane anaesthesia","authors":"V Jäntti ,&nbsp;E Sonkajärvi ,&nbsp;S Mustola ,&nbsp;S Rytky ,&nbsp;P Kiiski ,&nbsp;K Suominen","doi":"10.1016/S0168-5597(98)00005-7","DOIUrl":null,"url":null,"abstract":"<div><p><span><span>Cortical evoked responses to </span>median nerve<span><span> stimulation were recorded from 21 subjects during sevoflurane anaesthesia at the level of </span>burst suppression in EEG. The N20/P22 wave had the typical form of a negative wave postcentrally, and positive precentrally. The amplitude exceeded 4 </span></span><em>μ</em><span>V in all patients, making it easily visible without averaging on the low-amplitude suppression. These results show that two kinds of somatosensory evoked potential can be studied without averaging during EEG suppression in deep anaesthesia. One is the localised N20/P22 wave, which is seen regularly during suppression after stimuli with intervals exceeding 1 s. The other is the burst, involving the whole cortex, which is not evoked by every stimulus. We suggest that somatosensory evoked potentials can be monitored during sevoflurane-induced EEG suppression, and often can be evaluated reliably from a couple of single sweeps with stimulation interval exceeding 1 s. The enhancement of early cortical components of SEP, their adaptation to repeated stimuli, and the disappearance of later polysynaptic components during EEG suppression, give new possibilities to study the generators of SEP and the different effects of anaesthetics.</span></p></div>","PeriodicalId":100401,"journal":{"name":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","volume":"108 3","pages":"Pages 320-324"},"PeriodicalIF":0.0000,"publicationDate":"1998-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0168-5597(98)00005-7","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168559798000057","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

Abstract

Cortical evoked responses to median nerve stimulation were recorded from 21 subjects during sevoflurane anaesthesia at the level of burst suppression in EEG. The N20/P22 wave had the typical form of a negative wave postcentrally, and positive precentrally. The amplitude exceeded 4 μV in all patients, making it easily visible without averaging on the low-amplitude suppression. These results show that two kinds of somatosensory evoked potential can be studied without averaging during EEG suppression in deep anaesthesia. One is the localised N20/P22 wave, which is seen regularly during suppression after stimuli with intervals exceeding 1 s. The other is the burst, involving the whole cortex, which is not evoked by every stimulus. We suggest that somatosensory evoked potentials can be monitored during sevoflurane-induced EEG suppression, and often can be evaluated reliably from a couple of single sweeps with stimulation interval exceeding 1 s. The enhancement of early cortical components of SEP, their adaptation to repeated stimuli, and the disappearance of later polysynaptic components during EEG suppression, give new possibilities to study the generators of SEP and the different effects of anaesthetics.

单扫皮层体感诱发电位:七氟醚麻醉下的N20和诱发脉冲
记录了21例七氟醚麻醉下正中神经刺激的皮层诱发反应。N20/P22波呈中心后负波、中心前正波的典型形态。所有患者的振幅均超过4 μV,无需对低振幅抑制进行平均,可见性较好。结果表明,在深度麻醉下,两种体感诱发电位在脑电图抑制过程中可以不经平均地进行研究。一种是局部的N20/P22波,在刺激间隔超过1秒后的抑制期间有规律地看到。另一种是爆发,涉及整个皮层,并不是每一个刺激都能引起。我们认为,在七氟醚诱导的脑电图抑制期间,可以监测体感诱发电位,并且通常可以通过刺激间隔超过1秒的几次单次扫描来可靠地评估。SEP早期皮层成分的增强及其对重复刺激的适应,以及后期多突触成分在脑电图抑制期间的消失,为研究SEP的产生和麻醉的不同作用提供了新的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信