Automated measurement of erythrocyte sedimentation rate and its relation to red blood cell concentration and plasma proteins.

Hematology and cell therapy Pub Date : 1998-02-01
Y Imafuku, H Yoshida, S Greenfield, A Rabinovitch
{"title":"Automated measurement of erythrocyte sedimentation rate and its relation to red blood cell concentration and plasma proteins.","authors":"Y Imafuku,&nbsp;H Yoshida,&nbsp;S Greenfield,&nbsp;A Rabinovitch","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A new automated erythrocyte sedimentation rate (ESR) system, the SEDISYSTEM was evaluated for its stability and accuracy. It offers automated mixing of vacuum-collected blood for 5 minutes (min) and reading of the ESR for 20 min to generate values comparable with those of the Westergren method at 1 hour (h) and 2 h. The benefits are (1) simplified procedure, (2) reduction of biohazard and, (3) shortening of examination time. To evaluate the basic performance of this system, the stability of ESR values was first evaluated by keeping samples at room temperature for up to 20 h, during which time no remarkable change was observed. Next, a comparison between this system and the standard method of Westergren was conducted and good agreement was obtained. To determine the factors affecting ESR values, correlations were analyzed between the ESR obtained by SEDISYSTEM and the standard Westergren method for red blood cell concentration, hematocrit, and plasma proteins including fibrinogen, albumin and globulins (alpha1, alpha2, beta and gamma). Multiple regression analysis showed significant correlation with RBC, fibrinogen and gamma globulin. It is concluded from these results that SEDISYSTEM is a useful new tool for the measurement of ESR.</p>","PeriodicalId":73231,"journal":{"name":"Hematology and cell therapy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1998-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hematology and cell therapy","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A new automated erythrocyte sedimentation rate (ESR) system, the SEDISYSTEM was evaluated for its stability and accuracy. It offers automated mixing of vacuum-collected blood for 5 minutes (min) and reading of the ESR for 20 min to generate values comparable with those of the Westergren method at 1 hour (h) and 2 h. The benefits are (1) simplified procedure, (2) reduction of biohazard and, (3) shortening of examination time. To evaluate the basic performance of this system, the stability of ESR values was first evaluated by keeping samples at room temperature for up to 20 h, during which time no remarkable change was observed. Next, a comparison between this system and the standard method of Westergren was conducted and good agreement was obtained. To determine the factors affecting ESR values, correlations were analyzed between the ESR obtained by SEDISYSTEM and the standard Westergren method for red blood cell concentration, hematocrit, and plasma proteins including fibrinogen, albumin and globulins (alpha1, alpha2, beta and gamma). Multiple regression analysis showed significant correlation with RBC, fibrinogen and gamma globulin. It is concluded from these results that SEDISYSTEM is a useful new tool for the measurement of ESR.

红细胞沉降率的自动测量及其与红细胞浓度和血浆蛋白的关系。
sedissystem是一种新的自动红细胞沉降率(ESR)系统,对其稳定性和准确性进行了评估。它可以自动混合真空采集的血液5分钟(min),读取ESR 20分钟,产生与Westergren方法在1小时(h)和2小时(h)相当的值。其优点是(1)简化了程序,(2)减少了生物危害,(3)缩短了检查时间。为了评估该体系的基本性能,首先通过将样品在室温下保存20小时来评估ESR值的稳定性,在此期间没有观察到明显的变化。然后,将该体系与Westergren标准方法进行了比较,得到了较好的一致性。为了确定影响ESR值的因素,我们分析了sedissystem获得的ESR与标准Westergren方法在红细胞浓度、红细胞压积和血浆蛋白(包括纤维蛋白原、白蛋白和球蛋白(α 1、α 2、β和γ)方面的相关性。多元回归分析显示,红细胞、纤维蛋白原、丙种球蛋白与红细胞、纤维蛋白原、丙种球蛋白有显著相关性。结果表明,sedissystem是一种有用的ESR测量新工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信