[Multi-point contact (MPC) osteosynthesis plate. 1: Animal experiment histomorphologic studies in the Göttingen minipig].

IF 0.6 4区 医学 Q4 EMERGENCY MEDICINE
Unfallchirurgie Pub Date : 1997-12-01 DOI:10.1007/BF02628919
J F Hönig, H A Merten, E Ficker
{"title":"[Multi-point contact (MPC) osteosynthesis plate. 1: Animal experiment histomorphologic studies in the Göttingen minipig].","authors":"J F Hönig,&nbsp;H A Merten,&nbsp;E Ficker","doi":"10.1007/BF02628919","DOIUrl":null,"url":null,"abstract":"<p><p>Based on the results of clinical and animal studies as reported in the literature, the subimplant cortex becomes porous underneath conventional osteosynthesis plates with a flat surface. To solve this problem, we developed an implantable plate which creates multiple contact points between plate and bone, called the multi-point contact or MPC plate. In an experimental animal study conducted on 16 Göttingen minipigs we investigated the bone reaction beneath 2 different types of osteosynthesis plates: the conventional type with a flat interface versus the multi-point contact type. Both epiperiostal and subperiostal plating was performed on pig's intact tibiae. After an implantation period of 16 weeks, the results were documented and compared. It was shown that the osteal remodeling activity of the cortical bone adjacent to the plate increased under both plates up to the twelfth week, but declined towards the end of the study period. Compared to the MPC plate, a conspicuous remodeling front accompanied by porosis of the cortical bone adjacent to the plate was found underneath the conventional osteosynthesis plates with a flat surface-to-bone interface. The different subimplant reactions between the 2 plates can be best explained by the fact that intracortical implant-induced viscoelastic osteocyte diffusion is better under the MPC plate, whereas it is impaired under the conventional flat plate.</p>","PeriodicalId":29789,"journal":{"name":"Unfallchirurgie","volume":"23 6","pages":"227-37"},"PeriodicalIF":0.6000,"publicationDate":"1997-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02628919","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Unfallchirurgie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02628919","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 2

Abstract

Based on the results of clinical and animal studies as reported in the literature, the subimplant cortex becomes porous underneath conventional osteosynthesis plates with a flat surface. To solve this problem, we developed an implantable plate which creates multiple contact points between plate and bone, called the multi-point contact or MPC plate. In an experimental animal study conducted on 16 Göttingen minipigs we investigated the bone reaction beneath 2 different types of osteosynthesis plates: the conventional type with a flat interface versus the multi-point contact type. Both epiperiostal and subperiostal plating was performed on pig's intact tibiae. After an implantation period of 16 weeks, the results were documented and compared. It was shown that the osteal remodeling activity of the cortical bone adjacent to the plate increased under both plates up to the twelfth week, but declined towards the end of the study period. Compared to the MPC plate, a conspicuous remodeling front accompanied by porosis of the cortical bone adjacent to the plate was found underneath the conventional osteosynthesis plates with a flat surface-to-bone interface. The different subimplant reactions between the 2 plates can be best explained by the fact that intracortical implant-induced viscoelastic osteocyte diffusion is better under the MPC plate, whereas it is impaired under the conventional flat plate.

多点接触(MPC)接骨板。[1] Göttingen迷你猪的动物实验组织形态学研究。
根据文献报道的临床和动物研究结果,植入物下皮层在传统的平面骨接骨板下变得多孔。为了解决这个问题,我们开发了一种可植入的钢板,它可以在钢板和骨头之间产生多个接触点,称为多点接触或MPC钢板。在对16只Göttingen迷你猪进行的实验动物研究中,我们研究了两种不同类型的骨合成板下的骨反应:具有平面界面的传统类型与多点接触类型。对猪完整胫骨进行骨膜外和骨膜下电镀。植入16周后,记录并比较结果。结果显示,在第12周之前,两个钢板下与钢板相邻的皮质骨的骨重塑活动都有所增加,但在研究期结束时有所下降。与MPC接骨板相比,常规接骨板的下方有一个明显的重塑前沿,并伴有与接骨板相邻的皮质骨骨质疏松。两种板之间不同的植入物亚反应可以最好地解释为,MPC板下皮质内植入物诱导的粘弹性骨细胞扩散更好,而传统平板下则受损。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.40
自引率
25.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信