{"title":"Long sensory tracts (cuneate fascicle) in cervical somatosensory evoked potential after median nerve stimulation","authors":"Borut Prestor, Barbara Gnidovec, Peter Golob","doi":"10.1016/S0168-5597(97)00040-3","DOIUrl":null,"url":null,"abstract":"<div><p><span>Low amplitude high frequency waves (LHW) were investigated in normal and patient cervical somatosensory evoked potentials<span> after median nerve stimulation<span><span><span> (CSEP) in parallel to normal and patient conducted somatosensory evoked potentials (SEP) after tibial nerve stimulation. Normal recordings were obtained in five subjects undergoing </span>dorsal root<span><span> entry zone (DREZ) coagulation for pain relief. Patient recordings were obtained in 11 subjects suffering from either syringomyelia, </span>spinal cord tumour, or both. All recordings were made intraoperatively from the dorsal spinal cord surface using the subpial recording technique. Normal CSEP showed typical triphasic potential starting with an initial P9, followed by </span></span>N13 and a final positivity, P1. Numerous LHW were superimposed on slow triphasic potential. To improve the visibility of LHW, slow triphasic potential was removed from the original CSEP. Potentials thus obtained contained only high frequency components of CSEP, i.e. LHW. They were compared with conducted SEP after tibial nerve stimulation. Comparison revealed similarities in high frequency, low amplitude and general wave form, LHW thus showing characteristics of conducted potential. Duration was found to be significantly shorter than normal duration in both patient LHW (Student's </span></span></span><em>t</em>-test, <em>P</em><0.0005) and patient conducted SEP (Student's <em>t</em>-test, <em>P</em><span>=0.064). A shorter duration was associated with worsening of configuration in patient LHW and patient conducted SEP. These changes of LHW could not be connected with distortion of N13 seen in patient CSEP. A shorter duration and worsening of configuration in patient LHW were most prominent in cases with a loss of vibration and posture senses, but were also observed in cases where only pain and temperature senses were affected. We therefore concluded that cuneate fascicle is the most likely generator of LHW, although the participation of other cervical long sensory tracts, e.g. spinothalamic tract, cannot be ruled out.</span></p></div>","PeriodicalId":100401,"journal":{"name":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","volume":"104 6","pages":"Pages 470-479"},"PeriodicalIF":0.0000,"publicationDate":"1997-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0168-5597(97)00040-3","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0168559797000403","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
Low amplitude high frequency waves (LHW) were investigated in normal and patient cervical somatosensory evoked potentials after median nerve stimulation (CSEP) in parallel to normal and patient conducted somatosensory evoked potentials (SEP) after tibial nerve stimulation. Normal recordings were obtained in five subjects undergoing dorsal root entry zone (DREZ) coagulation for pain relief. Patient recordings were obtained in 11 subjects suffering from either syringomyelia, spinal cord tumour, or both. All recordings were made intraoperatively from the dorsal spinal cord surface using the subpial recording technique. Normal CSEP showed typical triphasic potential starting with an initial P9, followed by N13 and a final positivity, P1. Numerous LHW were superimposed on slow triphasic potential. To improve the visibility of LHW, slow triphasic potential was removed from the original CSEP. Potentials thus obtained contained only high frequency components of CSEP, i.e. LHW. They were compared with conducted SEP after tibial nerve stimulation. Comparison revealed similarities in high frequency, low amplitude and general wave form, LHW thus showing characteristics of conducted potential. Duration was found to be significantly shorter than normal duration in both patient LHW (Student's t-test, P<0.0005) and patient conducted SEP (Student's t-test, P=0.064). A shorter duration was associated with worsening of configuration in patient LHW and patient conducted SEP. These changes of LHW could not be connected with distortion of N13 seen in patient CSEP. A shorter duration and worsening of configuration in patient LHW were most prominent in cases with a loss of vibration and posture senses, but were also observed in cases where only pain and temperature senses were affected. We therefore concluded that cuneate fascicle is the most likely generator of LHW, although the participation of other cervical long sensory tracts, e.g. spinothalamic tract, cannot be ruled out.