{"title":"Peripheral colour contrast thresholds in ocular hypertension and glaucoma.","authors":"B Friström","doi":"10.1111/j.1600-0420.1997.tb00393.x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate a new test for peripheral colour contrast sensitivity as a tool for early diagnosis of glaucoma.</p><p><strong>Patients and methods: </strong>Peripheral colour contrast sensitivity was measured by a computer and colour monitor system developed by Arden and co-workers. The monitor displays an annulus subtending 25 degrees at the retina. During the test, 45 degrees of the annulus is removed in one of four quadrants. The patient is asked to identify this quadrant, first at suprathreshold levels and then as the colour contrast between the annulus and the background is varied in order to establish the threshold for identification. The tested colours were varied along the protan, deutan and tritan colour confusion axes, respectively. Thirty-three normal subjects, 22 glaucoma patients and 69 ocular hypertensive patients were examined. The ocular hypertensive patients were divided into a low risk group, a medium risk group and a high risk group.</p><p><strong>Results: </strong>The colour contrast thresholds for the glaucoma group and the high risk ocular hypertensive group were significantly (p < 0.001) higher for all three colour axes compared with the normal group. There were also significant (p < 0.05-0.001) differences for all axes between the glaucoma group on the one hand and the ocular hypertensive low risk group on the other hand. There were, however, overlaps in colour contrast thresholds between all groups.</p><p><strong>Conclusion: </strong>Although there is a large and statistically significant difference in average colour contrast thresholds between normals and glaucoma patients, it was difficult to find an appropriate cut-off point to separate the two groups. Further studies must clarify the influence of early stages of common diseases such as cataract, diabetes and age-related maculopathy on colour contrast sensitivity.</p>","PeriodicalId":7152,"journal":{"name":"Acta ophthalmologica Scandinavica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1997-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1600-0420.1997.tb00393.x","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta ophthalmologica Scandinavica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/j.1600-0420.1997.tb00393.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Purpose: To evaluate a new test for peripheral colour contrast sensitivity as a tool for early diagnosis of glaucoma.

Patients and methods: Peripheral colour contrast sensitivity was measured by a computer and colour monitor system developed by Arden and co-workers. The monitor displays an annulus subtending 25 degrees at the retina. During the test, 45 degrees of the annulus is removed in one of four quadrants. The patient is asked to identify this quadrant, first at suprathreshold levels and then as the colour contrast between the annulus and the background is varied in order to establish the threshold for identification. The tested colours were varied along the protan, deutan and tritan colour confusion axes, respectively. Thirty-three normal subjects, 22 glaucoma patients and 69 ocular hypertensive patients were examined. The ocular hypertensive patients were divided into a low risk group, a medium risk group and a high risk group.

Results: The colour contrast thresholds for the glaucoma group and the high risk ocular hypertensive group were significantly (p < 0.001) higher for all three colour axes compared with the normal group. There were also significant (p < 0.05-0.001) differences for all axes between the glaucoma group on the one hand and the ocular hypertensive low risk group on the other hand. There were, however, overlaps in colour contrast thresholds between all groups.

Conclusion: Although there is a large and statistically significant difference in average colour contrast thresholds between normals and glaucoma patients, it was difficult to find an appropriate cut-off point to separate the two groups. Further studies must clarify the influence of early stages of common diseases such as cataract, diabetes and age-related maculopathy on colour contrast sensitivity.

高眼压和青光眼的周围颜色对比阈值。
目的:评价一种新的外周颜色对比敏感度测试方法作为青光眼早期诊断的工具。患者和方法:外围颜色对比敏感度由Arden及其同事开发的计算机和颜色监测系统测量。显示器显示视网膜上有一个25度的环。在测试期间,在四个象限之一中移除45度的环空。患者被要求识别该象限,首先在阈值以上水平,然后随着环和背景之间的颜色对比的变化,以建立识别的阈值。测试的颜色分别沿蛋白、多晶石和三晶石的颜色混淆轴变化。对33名正常人、22名青光眼患者和69名高眼压患者进行了检查。将高眼压患者分为低危组、中危组和高危组。结果:青光眼组和高危高眼压组的三个色轴颜色对比阈值均显著高于正常组(p < 0.001)。青光眼组与高眼压低危组在各轴上的差异均有统计学意义(p < 0.05-0.001)。然而,所有组之间的颜色对比阈值存在重叠。结论:虽然正常人和青光眼患者的平均颜色对比阈值存在较大且有统计学意义的差异,但很难找到一个合适的分界点来区分两组。进一步的研究必须阐明早期常见疾病如白内障、糖尿病和年龄相关性黄斑病变对颜色对比敏感性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信