J. Troccaz, N. Laieb, P. Vassal, Y. Menguy, P. Cinquin, M. Bolla, J.Y. Giraud
{"title":"Patient setup optimization for external conformal radiotherapy","authors":"J. Troccaz, N. Laieb, P. Vassal, Y. Menguy, P. Cinquin, M. Bolla, J.Y. Giraud","doi":"10.1002/(SICI)1522-712X(1995)1:2<113::AID-IGS7>3.0.CO;2-D","DOIUrl":null,"url":null,"abstract":"<p>The aim of conformal radiotherapy is to deliver precisely a specific dose of radiation to a planning target volume, concurrently radiating as little healthy tissue and organs as possible. This can be accomplished only with the accurate positioning of the patient with respect to the radiotherapy system. In this paper, we describe a system to achieve a higher overall accuracy in the delivery of a prostatic radiation boost for treatment of carcinoma of the prostate. The system is based on the use of ultrasound images for measuring the actual position of the patient's prostate just before the radiation. Since these images are registered with pretreatment computed tomography or magnetic resonance imaging, the position and orientation of the planning target volume are computed with respect to the radiotherapy system and can be corrected as needed. This system is under clinical evaluation. <i>J Image Guid Surg 1:113–120 (1995).</i> © 1995 Wiley-Liss, Inc.</p>","PeriodicalId":79505,"journal":{"name":"Journal of image guided surgery","volume":"1 2","pages":"113-120"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of image guided surgery","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291522-712X%281995%291%3A2%3C113%3A%3AAID-IGS7%3E3.0.CO%3B2-D","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30
Abstract
The aim of conformal radiotherapy is to deliver precisely a specific dose of radiation to a planning target volume, concurrently radiating as little healthy tissue and organs as possible. This can be accomplished only with the accurate positioning of the patient with respect to the radiotherapy system. In this paper, we describe a system to achieve a higher overall accuracy in the delivery of a prostatic radiation boost for treatment of carcinoma of the prostate. The system is based on the use of ultrasound images for measuring the actual position of the patient's prostate just before the radiation. Since these images are registered with pretreatment computed tomography or magnetic resonance imaging, the position and orientation of the planning target volume are computed with respect to the radiotherapy system and can be corrected as needed. This system is under clinical evaluation. J Image Guid Surg 1:113–120 (1995). © 1995 Wiley-Liss, Inc.
体外适形放疗患者设置优化
适形放射治疗的目的是精确地将特定剂量的辐射输送到计划的目标体积,同时尽可能少地辐射健康组织和器官。这只能通过患者相对于放疗系统的准确定位来实现。在本文中,我们描述了一个系统,以实现更高的整体准确性,在提供前列腺辐射促进治疗前列腺癌。该系统是基于使用超声波图像来测量患者在放疗前前列腺的实际位置。由于这些图像是通过预处理计算机断层扫描或磁共振成像进行配准的,因此可以计算出计划靶体相对于放疗系统的位置和方向,并可以根据需要进行校正。该系统正在临床评估中。[J] .中华影像杂志(英文版);©1995 Wiley-Liss, Inc
本文章由计算机程序翻译,如有差异,请以英文原文为准。