Thilaka S. Sumanaweera Ph.D., John R. Adler M.D., Gary H. Glover Ph.D., Paul F. Hemler Ph.D., Petra A. van den Elsen M.D., Ph.D., David Martin M.D., Sandy Napel Ph.D.
求助PDF
{"title":"Method for correcting magnetic resonance image distortion for frame-based stereotactic surgery, with preliminary results","authors":"Thilaka S. Sumanaweera Ph.D., John R. Adler M.D., Gary H. Glover Ph.D., Paul F. Hemler Ph.D., Petra A. van den Elsen M.D., Ph.D., David Martin M.D., Sandy Napel Ph.D.","doi":"10.1002/(SICI)1522-712X(1995)1:3<151::AID-IGS4>3.0.CO;2-9","DOIUrl":null,"url":null,"abstract":"<p>We previously described a technique for correcting patient-specific magnetic field inhomogeneity spatial distortion in magnetic resonance images (MRI), which was not applicable to patients fitted with MRI-compatible stereotactic fiducial frames. Here we describe an improvement to the technique that permits application for these patients. Measurements with a cadaver head show that this method achieves MRI stereotactic localization accuracy of 1 mm. <i>J Image Guid Surg 1:151–157 (1995).</i> © 1996 Wiley-Liss, Inc.</p>","PeriodicalId":79505,"journal":{"name":"Journal of image guided surgery","volume":"1 3","pages":"151-157"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of image guided surgery","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291522-712X%281995%291%3A3%3C151%3A%3AAID-IGS4%3E3.0.CO%3B2-9","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25
引用
批量引用
Abstract
We previously described a technique for correcting patient-specific magnetic field inhomogeneity spatial distortion in magnetic resonance images (MRI), which was not applicable to patients fitted with MRI-compatible stereotactic fiducial frames. Here we describe an improvement to the technique that permits application for these patients. Measurements with a cadaver head show that this method achieves MRI stereotactic localization accuracy of 1 mm. J Image Guid Surg 1:151–157 (1995). © 1996 Wiley-Liss, Inc.
基于框架立体定向手术的磁共振图像畸变校正方法及初步结果
我们之前描述了一种校正磁共振图像(MRI)中患者特异性磁场不均匀性空间畸变的技术,该技术不适用于配备MRI兼容立体定向基准框架的患者。在这里,我们描述了一种改进的技术,允许这些患者的应用。对尸体头部的测量表明,该方法的MRI立体定向定位精度为1mm。[J]中华影像杂志(英文版);©1996 Wiley-Liss, Inc
本文章由计算机程序翻译,如有差异,请以英文原文为准。