Doppler echocardiographic assessment of the new ATS medical prosthetic valve in the aortic position.

American journal of cardiac imaging Pub Date : 1996-10-01
H Karpuz, X Jeanrenaud, M Hurni, N Aebischer, J Koerfer, A Fischer, P Ruchat, F Stumpe, H Sadeghi, L Kappenberger
{"title":"Doppler echocardiographic assessment of the new ATS medical prosthetic valve in the aortic position.","authors":"H Karpuz,&nbsp;X Jeanrenaud,&nbsp;M Hurni,&nbsp;N Aebischer,&nbsp;J Koerfer,&nbsp;A Fischer,&nbsp;P Ruchat,&nbsp;F Stumpe,&nbsp;H Sadeghi,&nbsp;L Kappenberger","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Advancing The Standard (ATS) Medical (ATS Medical Inc., Minneapolis, MN) is a new mechanical bileaflet valve, composed of pyrolitic carbon. The aim of this study was to define in a blinded manner the Doppler echocardiographic characteristics of normally functioning ATS Medical prostheses with respect to their size. Forty consecutive patients (29 men, mean age 58 +/- 13 years), clinically stable, and without evidence of valve dysfunction, were studied from 1993 to 1995. Doppler echocardiography was performed at least 3 months after valve replacement with ATS Medical valves (5 n degrees 21, 8 n degrees 23, 12 n degrees 25, 10 n degrees 27, 5 n degrees 29). Maximum and mean transprosthetic pressure gradients were calculated by the simplified Bernoulli equation. Functional valve surface area was assessed by the continuity equation using the external diameter of the prostheses to calculate the subaortic surface area. The Doppler velocity index was obtained by the ratio of subaortic and transaortic velocities and the performance index was calculated dividing the effective orifice area by the actual orifice area. For the most commonly used aortic valve (25 mm), the maximum pressure gradient was 17 +/- 8 mmHg, the mean gradient 11 +/- 4 mmHg, the functional surface area 2.2 +/- 0.4 cm2, the Doppler velocity index 0.44 +/- 0.07, and the performance index 0.68 +/- 0.11. This study provides the normal range for Doppler hemodynamic characteristics of the various sizes of the ATS valve.</p>","PeriodicalId":79315,"journal":{"name":"American journal of cardiac imaging","volume":"10 4","pages":"254-60"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of cardiac imaging","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Advancing The Standard (ATS) Medical (ATS Medical Inc., Minneapolis, MN) is a new mechanical bileaflet valve, composed of pyrolitic carbon. The aim of this study was to define in a blinded manner the Doppler echocardiographic characteristics of normally functioning ATS Medical prostheses with respect to their size. Forty consecutive patients (29 men, mean age 58 +/- 13 years), clinically stable, and without evidence of valve dysfunction, were studied from 1993 to 1995. Doppler echocardiography was performed at least 3 months after valve replacement with ATS Medical valves (5 n degrees 21, 8 n degrees 23, 12 n degrees 25, 10 n degrees 27, 5 n degrees 29). Maximum and mean transprosthetic pressure gradients were calculated by the simplified Bernoulli equation. Functional valve surface area was assessed by the continuity equation using the external diameter of the prostheses to calculate the subaortic surface area. The Doppler velocity index was obtained by the ratio of subaortic and transaortic velocities and the performance index was calculated dividing the effective orifice area by the actual orifice area. For the most commonly used aortic valve (25 mm), the maximum pressure gradient was 17 +/- 8 mmHg, the mean gradient 11 +/- 4 mmHg, the functional surface area 2.2 +/- 0.4 cm2, the Doppler velocity index 0.44 +/- 0.07, and the performance index 0.68 +/- 0.11. This study provides the normal range for Doppler hemodynamic characteristics of the various sizes of the ATS valve.

新型ATS医用人工瓣膜在主动脉位置的多普勒超声心动图评价。
advance The Standard (ATS) Medical (ATS Medical Inc., Minneapolis, MN)是一种新型的机械双小瓣阀,由热解碳组成。本研究的目的是以盲法确定正常功能ATS医学假体的多普勒超声心动图特征及其尺寸。从1993年到1995年,连续研究了40例患者(29例男性,平均年龄58±13岁),临床稳定,无瓣膜功能障碍证据。在ATS医用瓣膜置换术后至少3个月进行多普勒超声心动图检查(5 n度21、8 n度23、12 n度25、10 n度27、5 n度29)。通过简化伯努利方程计算最大和平均假体压力梯度。采用连续性方程评估功能瓣膜表面积,利用假体外径计算主动脉下表面积。通过主动脉下流速与经主动脉流速之比得到多普勒速度指数,用有效孔口面积除以实际孔口面积计算性能指数。最常用的主动脉瓣(25 mm),最大压力梯度为17 +/- 8 mmHg,平均梯度为11 +/- 4 mmHg,功能表面积为2.2 +/- 0.4 cm2,多普勒速度指数为0.44 +/- 0.07,功能指数为0.68 +/- 0.11。本研究提供了不同尺寸ATS瓣膜的多普勒血流动力学特性的正常范围。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信