Clasping system with rotational path of insertion Part 3. Clinical application.

T Yamaga, T Nokubi
{"title":"Clasping system with rotational path of insertion Part 3. Clinical application.","authors":"T Yamaga,&nbsp;T Nokubi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the retentive forces of rotational path clasping systems. Twelve rotational path removable partial dentures were applied in the clinical field and the retentive forces of the dentures were measured. The following results were obtained; 1. Retentive forces of the 12 dentures were varied from 187g to 1,380g. 2. As distances between abutment teeth increased from 10.9 mm to 27.7 mm, the retentive forces decreased accordingly (r = -0.56; p < 0.05). 3. As the inclination of the proximal surfaces was increased from 0 degrees to 50 degrees, the retentive forces showed a tendency to increase (r = +0.47). 4. Longer distances between abutment teeth as well as smaller inclination of proximal surface were present in three patients who answered that their dentures showed movement while eating. From these results, it became clear that the distance between abutment teeth and the inclination of the proximal surfaces greatly influenced the retention of the rotational path clasping system in the clinical field.</p>","PeriodicalId":76655,"journal":{"name":"The Journal of Osaka University Dental School","volume":"34 ","pages":"57-63"},"PeriodicalIF":0.0000,"publicationDate":"1994-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Osaka University Dental School","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigated the retentive forces of rotational path clasping systems. Twelve rotational path removable partial dentures were applied in the clinical field and the retentive forces of the dentures were measured. The following results were obtained; 1. Retentive forces of the 12 dentures were varied from 187g to 1,380g. 2. As distances between abutment teeth increased from 10.9 mm to 27.7 mm, the retentive forces decreased accordingly (r = -0.56; p < 0.05). 3. As the inclination of the proximal surfaces was increased from 0 degrees to 50 degrees, the retentive forces showed a tendency to increase (r = +0.47). 4. Longer distances between abutment teeth as well as smaller inclination of proximal surface were present in three patients who answered that their dentures showed movement while eating. From these results, it became clear that the distance between abutment teeth and the inclination of the proximal surfaces greatly influenced the retention of the rotational path clasping system in the clinical field.

带旋转插入路径的卡扣系统第3部分。临床应用。
本文研究了旋转路径夹持体系的固位力。将12个可移动局部义齿应用于临床,测量义齿的固位力。得到以下结果:1. 12个义齿的固位力从187g到1380g不等。2. 随着基牙间距从10.9 mm增加到27.7 mm,固位力相应减小(r = -0.56;P < 0.05)。3.随着近端表面倾斜度从0度增加到50度,固位力有增加的趋势(r = +0.47)。4. 有3例患者在进食时假牙有运动现象,其基牙之间的距离较长,近端表面的倾斜度较小。从这些结果可以看出,基牙之间的距离和近端表面的倾斜度在临床上对旋转路径卡箍系统的固位有很大的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信