{"title":"Detection of N. meningitidis group B antigens by MB-Dot-ELISA in patients with meningitis.","authors":"G Alkmin M das, I M Landgraf, S H Shimizu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Infection with Neisseria meningitidis group B has been difficult to detect, partly because this bacterial group's polysaccharide is a weak immunogen. This article describes work carried out to test a new procedure (MB-Dot-ELISA) employing a high-titered horse antiserum for detection of N. meningitidis group B antigens. The study assayed cerebrospinal fluid samples from 585 subjects, 574 with suspected meningitis cases and 11 with neurologic disorders. The results of the assay indicated a sensitivity of 0.991 and a specificity of 0.826. These results were superior to those obtained with latex agglutination and in substantial agreement with the results of counterimmunoelectrophoresis and bacteriologic methods. Overall, the MB-Dot-ELISA was found to be sensitive, inexpensive, and suitable for public health laboratory investigations.</p>","PeriodicalId":75654,"journal":{"name":"Bulletin of the Pan American Health Organization","volume":"30 3","pages":"212-7"},"PeriodicalIF":0.0000,"publicationDate":"1996-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin of the Pan American Health Organization","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Infection with Neisseria meningitidis group B has been difficult to detect, partly because this bacterial group's polysaccharide is a weak immunogen. This article describes work carried out to test a new procedure (MB-Dot-ELISA) employing a high-titered horse antiserum for detection of N. meningitidis group B antigens. The study assayed cerebrospinal fluid samples from 585 subjects, 574 with suspected meningitis cases and 11 with neurologic disorders. The results of the assay indicated a sensitivity of 0.991 and a specificity of 0.826. These results were superior to those obtained with latex agglutination and in substantial agreement with the results of counterimmunoelectrophoresis and bacteriologic methods. Overall, the MB-Dot-ELISA was found to be sensitive, inexpensive, and suitable for public health laboratory investigations.