A Kitajima, K Yoshii, H Komatsu, S Ishimitsu, S Okada
{"title":"[The Cyanocobalamin Reference Standard (Control 931) of the National Institute of Health Sciences].","authors":"A Kitajima, K Yoshii, H Komatsu, S Ishimitsu, S Okada","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Raw cyanocobalamin material was tested for preparation of the \"Cyanocobalamin Reference Standard (Control 931)\". Analytical data obtained were as follows: loss on drying, 4.2%; infrared spectrum, the same as that of the JP Cyanocobalamin Reference Standard (Control 901); thin-layer chromatography, four impurities were detected; high-performance liquid chromatography (HPLC), seven to eight kinds of impurities were detected, but the total amount of impurities was only 1.0 +/- 0.52% (n = 5); assay results, 100.6% by spectrophotometry in the JP XII and 99.7% by HPLC. Based on the above findings, the raw material was authorized as the JP Cyanocobalamin Reference Standard (Control 931).</p>","PeriodicalId":11656,"journal":{"name":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","volume":" 112","pages":"170-4"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Raw cyanocobalamin material was tested for preparation of the "Cyanocobalamin Reference Standard (Control 931)". Analytical data obtained were as follows: loss on drying, 4.2%; infrared spectrum, the same as that of the JP Cyanocobalamin Reference Standard (Control 901); thin-layer chromatography, four impurities were detected; high-performance liquid chromatography (HPLC), seven to eight kinds of impurities were detected, but the total amount of impurities was only 1.0 +/- 0.52% (n = 5); assay results, 100.6% by spectrophotometry in the JP XII and 99.7% by HPLC. Based on the above findings, the raw material was authorized as the JP Cyanocobalamin Reference Standard (Control 931).