W A Anderson, P J McClure, A C Baird-Parker, M B Cole
{"title":"The application of a log-logistic model to describe the thermal inactivation of Clostridium botulinum 213B at temperatures below 121.1 degrees C.","authors":"W A Anderson, P J McClure, A C Baird-Parker, M B Cole","doi":"10.1111/j.1365-2672.1996.tb03221.x","DOIUrl":null,"url":null,"abstract":"<p><p>In this work, the death of Clostridium botulinum 213B was measured at temperatures between 101 degrees C and 121 degrees C. It was found that at all temperatures tested, survivor curves deviated from log-linearity which prevented their description using traditional first order kinetics. The survivor curves were better described using a vitalistic approach and the log-logistic transformation proposed by Cole et al. (1993). A single equation was derived to describe all survivor curves over the temperature range tested and a comparison of predicted and measured data showed good correlation. The implications of the use of the vitalistic approach to the validity of the 'minimum botulinum cook' is discussed.</p>","PeriodicalId":22599,"journal":{"name":"The Journal of applied bacteriology","volume":"80 3","pages":"283-90"},"PeriodicalIF":0.0000,"publicationDate":"1996-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1111/j.1365-2672.1996.tb03221.x","citationCount":"110","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of applied bacteriology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/j.1365-2672.1996.tb03221.x","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 110
Abstract
In this work, the death of Clostridium botulinum 213B was measured at temperatures between 101 degrees C and 121 degrees C. It was found that at all temperatures tested, survivor curves deviated from log-linearity which prevented their description using traditional first order kinetics. The survivor curves were better described using a vitalistic approach and the log-logistic transformation proposed by Cole et al. (1993). A single equation was derived to describe all survivor curves over the temperature range tested and a comparison of predicted and measured data showed good correlation. The implications of the use of the vitalistic approach to the validity of the 'minimum botulinum cook' is discussed.