W Schleifer, U Bissinger, H Guggenberger, D Heuser
{"title":"Variance of cardiorespiratory parameters during gynaecological surgery with CO2-pneumoperitoneum.","authors":"W Schleifer, U Bissinger, H Guggenberger, D Heuser","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Laparoscopic procedures with CO2-pneumoperitoneum are used widely in gynaecology and surgery. The effects of a 15 degrees head-down position, different intra-abdominal pressures (IAP) and CO2-insufflation flows on cardiorespiratory parameters were studied prospectively in 18 gyneacologic patients under general anaesthesia. The 15 degrees head-down position led to significant changes in heart rate (-6%) and in central venous pressure (+53%). Furthermore, significant changes under commonly used conditions for gynaecological laparoscopy (IAP 9mmHg, CO2-insufflation flow 2.41/ min., 15 degrees head-down position) were found in heart rate (+16%), systolic blood pressure (+21%), diastolic blood pressure (+26%), central venous pressure (+57%), peak inspiratory pressure (+26%), end-tidal CO2-concentration (+19%), central venous pCO2 (+21%), and central venous pH (-7%). On examination of variable pressure and insufflation flows (IAP 3, 9, and 15mmHg; CO2-insufflation flows 1.2, 2.4, and 6.0 1/min.), increasing changes in heart rate (7% - 24%), diastolic blood pressure (22% - 33%), central venous pressure (30% - 59%) and peak inspiratory pressure (10% - 43%) correlated with increasing IAP. However, they were independent of CO2-insufflation flows. The results demonstrate that CO2-pneumoperitoneum causes marked changes in cardiorespiratory parameters, but these do not exceed levels commonly regarded as safe in ASA class I and II patients.</p>","PeriodicalId":79337,"journal":{"name":"Endoscopic surgery and allied technologies","volume":"3 4","pages":"167-70"},"PeriodicalIF":0.0000,"publicationDate":"1995-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopic surgery and allied technologies","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Laparoscopic procedures with CO2-pneumoperitoneum are used widely in gynaecology and surgery. The effects of a 15 degrees head-down position, different intra-abdominal pressures (IAP) and CO2-insufflation flows on cardiorespiratory parameters were studied prospectively in 18 gyneacologic patients under general anaesthesia. The 15 degrees head-down position led to significant changes in heart rate (-6%) and in central venous pressure (+53%). Furthermore, significant changes under commonly used conditions for gynaecological laparoscopy (IAP 9mmHg, CO2-insufflation flow 2.41/ min., 15 degrees head-down position) were found in heart rate (+16%), systolic blood pressure (+21%), diastolic blood pressure (+26%), central venous pressure (+57%), peak inspiratory pressure (+26%), end-tidal CO2-concentration (+19%), central venous pCO2 (+21%), and central venous pH (-7%). On examination of variable pressure and insufflation flows (IAP 3, 9, and 15mmHg; CO2-insufflation flows 1.2, 2.4, and 6.0 1/min.), increasing changes in heart rate (7% - 24%), diastolic blood pressure (22% - 33%), central venous pressure (30% - 59%) and peak inspiratory pressure (10% - 43%) correlated with increasing IAP. However, they were independent of CO2-insufflation flows. The results demonstrate that CO2-pneumoperitoneum causes marked changes in cardiorespiratory parameters, but these do not exceed levels commonly regarded as safe in ASA class I and II patients.