Electric field plethysmography signals of the human thorax as determined by a 2-D FE-model.

Medical progress through technology Pub Date : 1995-01-01
P Nopp, H Pfützner, K Bögl, H Nakesch, C Ruhsam
{"title":"Electric field plethysmography signals of the human thorax as determined by a 2-D FE-model.","authors":"P Nopp,&nbsp;H Pfützner,&nbsp;K Bögl,&nbsp;H Nakesch,&nbsp;C Ruhsam","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Electric field plethysmography (EFPG) signals of the human thorax consist of a baseline component, a respiratory component and a cardiac component. This paper investigates to what extent a two-dimensional finite-element model of the human thorax can serve as a tool for signal prediction allowing for both optimisation of electrode position and effective signal interpretation. In the model inspiration is taken into account by decreasing lung conductivity. Modelling of cardiac activity involves heart geometry changes and lung conductivity increase. Comparison with experiments shows that the model is more effective for strip than spot electrodes for current injection. Modelling results suggest that the thorax behaves approximately as a homogeneous structure with an inspiratory conductivity increase of about 5%. Two electrode pairs are preferable for monitoring respiration in general. As cardiac activity involves two counter-acting signal sources in the thorax, optimum electrode position is obtained using four separated electrodes. However, recommendable positions for two electrode pairs are on the left sternal and right parasternal line. The investigation shows that in providing a proper modelling of respiration and cardiac activity, a 2-D model provides a practical tool for modelling EFPG signals with the cost of a few structural and systematical restrictions.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 3","pages":"135-45"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical progress through technology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electric field plethysmography (EFPG) signals of the human thorax consist of a baseline component, a respiratory component and a cardiac component. This paper investigates to what extent a two-dimensional finite-element model of the human thorax can serve as a tool for signal prediction allowing for both optimisation of electrode position and effective signal interpretation. In the model inspiration is taken into account by decreasing lung conductivity. Modelling of cardiac activity involves heart geometry changes and lung conductivity increase. Comparison with experiments shows that the model is more effective for strip than spot electrodes for current injection. Modelling results suggest that the thorax behaves approximately as a homogeneous structure with an inspiratory conductivity increase of about 5%. Two electrode pairs are preferable for monitoring respiration in general. As cardiac activity involves two counter-acting signal sources in the thorax, optimum electrode position is obtained using four separated electrodes. However, recommendable positions for two electrode pairs are on the left sternal and right parasternal line. The investigation shows that in providing a proper modelling of respiration and cardiac activity, a 2-D model provides a practical tool for modelling EFPG signals with the cost of a few structural and systematical restrictions.

由二维有限元模型确定的人类胸腔的电场体积脉搏信号。
人体胸腔的电场脉搏波(EFPG)信号由基线成分、呼吸成分和心脏成分组成。本文研究了人类胸腔的二维有限元模型在多大程度上可以作为信号预测的工具,允许优化电极位置和有效的信号解释。在模型中,吸气通过降低肺电导率来考虑。心脏活动的建模涉及心脏几何形状的变化和肺电导率的增加。实验结果表明,该模型对带状电极的电流注入比点状电极更有效。模拟结果表明,胸腔的行为近似为均匀结构,吸入电导率增加约5%。一般来说,两个电极对更适合用于监测呼吸。由于心脏活动涉及胸腔内的两个反向信号源,因此使用四个分离的电极获得最佳电极位置。然而,两对电极的推荐位置是在左胸骨线和右胸骨旁线。研究表明,在提供呼吸和心脏活动的适当建模时,二维模型为建模EFPG信号提供了一个实用的工具,但代价是一些结构和系统的限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书