U Fischer, R Vosshenrich, L Kopka, O Kahlen, E Grabbe
{"title":"[Contrast medium assisted dynamic MR-mammography after diagnostic and therapeutic interventions on the breast].","authors":"U Fischer, R Vosshenrich, L Kopka, O Kahlen, E Grabbe","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In a retrospective study, the authors evaluated the signal behavior of 150 patients after intervention in the breast (40 fine-needle biopsies, 10 core biopsies, 50 open biopsies, 50 tumor-ectomies with additional irradiation therapy). The MR imaging was performed on 1.5-Tesla whole-body scanners using T1-WI GRE sequences in 2D FLASH technique before and 5 times after i.v. application of 0.1 mmol gadopentetate-dimeglumine per kg body weight. There was no signal enhancement after fine-needle biopsy. Hematoma due to core biopsy caused signal increase in every 5th patient. Enhancement after open biopsy was no more visible 6 months postoperatively. 12 months after tumorectomy and radiation therapy, most patients showed no more signal enhancement. In conclusion, MR mammography can be performed after fine-needle biopsy without problems. In case of core biopsy, hematoma should be excluded by sonography before. MR mammography should not be performed within 6 months after open biopsy, or within 12 months after tumorectomy and radiation therapy.</p>","PeriodicalId":77035,"journal":{"name":"Bildgebung = Imaging","volume":"63 2","pages":"94-100"},"PeriodicalIF":0.0000,"publicationDate":"1996-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bildgebung = Imaging","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In a retrospective study, the authors evaluated the signal behavior of 150 patients after intervention in the breast (40 fine-needle biopsies, 10 core biopsies, 50 open biopsies, 50 tumor-ectomies with additional irradiation therapy). The MR imaging was performed on 1.5-Tesla whole-body scanners using T1-WI GRE sequences in 2D FLASH technique before and 5 times after i.v. application of 0.1 mmol gadopentetate-dimeglumine per kg body weight. There was no signal enhancement after fine-needle biopsy. Hematoma due to core biopsy caused signal increase in every 5th patient. Enhancement after open biopsy was no more visible 6 months postoperatively. 12 months after tumorectomy and radiation therapy, most patients showed no more signal enhancement. In conclusion, MR mammography can be performed after fine-needle biopsy without problems. In case of core biopsy, hematoma should be excluded by sonography before. MR mammography should not be performed within 6 months after open biopsy, or within 12 months after tumorectomy and radiation therapy.