S Okada, A Kitajima, T Tanimoto, H Suzuki, M Satake
{"title":"[Glycyrrhitinic acid reference standard (Control 941) of the National Institute of Health Sciences].","authors":"S Okada, A Kitajima, T Tanimoto, H Suzuki, M Satake","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The raw material of glycyrrhitinic acid was examined for preparation of the \"Glycyrrhitinic Acid Reference Standard\". The candidate material was evaluated physico-chemically by a collaborative study in which five laboratories participated. Analytical data obtained were as follows: UV spectrum, lambda max = 251 nm and specific absorbance E1%1cm (EtOH) at the lambda max = 145; IR spectrum, specific absorption numbers were at 1719, 1654, 1216, and 1170 cm-1; thin-layer chromatography, some laboratories detected a trace amount of one spot and others not detected; high-performance liquid chromatography, 2-6 impurities were detected and the amount of any impurities were estimated to be less than 0.2% and the total amount less than 0.5%. Based on the above results, the candidate material was authorized as the Glycyrrhitinic Acid Reference Standard of National Institute of Health Sciences.</p>","PeriodicalId":11656,"journal":{"name":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The raw material of glycyrrhitinic acid was examined for preparation of the "Glycyrrhitinic Acid Reference Standard". The candidate material was evaluated physico-chemically by a collaborative study in which five laboratories participated. Analytical data obtained were as follows: UV spectrum, lambda max = 251 nm and specific absorbance E1%1cm (EtOH) at the lambda max = 145; IR spectrum, specific absorption numbers were at 1719, 1654, 1216, and 1170 cm-1; thin-layer chromatography, some laboratories detected a trace amount of one spot and others not detected; high-performance liquid chromatography, 2-6 impurities were detected and the amount of any impurities were estimated to be less than 0.2% and the total amount less than 0.5%. Based on the above results, the candidate material was authorized as the Glycyrrhitinic Acid Reference Standard of National Institute of Health Sciences.