[Theoretical principles and technical realization of high resolution nuclear magnetic resonance tomography with the example of a dedicated coil system].
J Mäurer, H Requardt, T Herrling, F D Knollmann, H Schedel, T J Vogl, R Felix
{"title":"[Theoretical principles and technical realization of high resolution nuclear magnetic resonance tomography with the example of a dedicated coil system].","authors":"J Mäurer, H Requardt, T Herrling, F D Knollmann, H Schedel, T J Vogl, R Felix","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The theory of high-resolution magnetic resonance imaging (MRI) and the physical properties of a dedicated coil system with its clinical application are reviewed. To evaluate the spatial resolution of the system, a phantom sample was depicted by a transverse T1-weighted sequence (time of repetition 500 ms, time of echo 25 ms, 256 x 256 matrix, 3 acquisitions, field of view 25 mm2). Relative signal intensity decrease was less using the 5-cm coil, as signal intensity field distribution depends on coil diameter. The phantom appeared as an attainable resolution of 100-microns pixel width using the 2.5-cm coil. For the 5-cm coil the pixel width was 200 microns, not accomplishing clear resolution of the phantom. Coil head choice depends on the anatomic depth of the target organ. Work-up of the skin and musculoskeletal lesions is the main indication for high-resolution MRI using surface coils.</p>","PeriodicalId":77035,"journal":{"name":"Bildgebung = Imaging","volume":"63 1","pages":"40-6"},"PeriodicalIF":0.0000,"publicationDate":"1996-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bildgebung = Imaging","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The theory of high-resolution magnetic resonance imaging (MRI) and the physical properties of a dedicated coil system with its clinical application are reviewed. To evaluate the spatial resolution of the system, a phantom sample was depicted by a transverse T1-weighted sequence (time of repetition 500 ms, time of echo 25 ms, 256 x 256 matrix, 3 acquisitions, field of view 25 mm2). Relative signal intensity decrease was less using the 5-cm coil, as signal intensity field distribution depends on coil diameter. The phantom appeared as an attainable resolution of 100-microns pixel width using the 2.5-cm coil. For the 5-cm coil the pixel width was 200 microns, not accomplishing clear resolution of the phantom. Coil head choice depends on the anatomic depth of the target organ. Work-up of the skin and musculoskeletal lesions is the main indication for high-resolution MRI using surface coils.