Digital dynamic range expansion applied to X-ray densitometric analysis of total hip replacement

M. Viceconti , F. Baruffaldi , W. Gaiba , A. Toni , A. Sudanese , A. Giunti
{"title":"Digital dynamic range expansion applied to X-ray densitometric analysis of total hip replacement","authors":"M. Viceconti ,&nbsp;F. Baruffaldi ,&nbsp;W. Gaiba ,&nbsp;A. Toni ,&nbsp;A. Sudanese ,&nbsp;A. Giunti","doi":"10.1016/0141-5425(93)90094-F","DOIUrl":null,"url":null,"abstract":"<div><p>Due to the presence of the stiff prosthetic stem fitted in the medullary canal during total his replacement, the surrounding cortex of the femur changes its density over time. This bone remodelling takes place with every type of total hip prosthesis; however, its intensity may vary between prostheses and patients. In the worst cases this process can lead to the late failure of the implant. To monitor such bone density evolution, we are developing a tailored Computer-aided Densitometric Image Analysis system (the major part of this our system uses an 8-bit commercial hardware with 256 levels of grey). The equivalent dynamic range of an X-ray picture is about 10 bits. In this paper we present a method to overcome these hardware limitations by improving the software. Using a double-exposure acquisition it is possible to build a 9-bit image that is good enough for most applications involving bone density measurement.</p></div>","PeriodicalId":75992,"journal":{"name":"Journal of biomedical engineering","volume":"15 1","pages":"Pages 57-59"},"PeriodicalIF":0.0000,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0141-5425(93)90094-F","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/014154259390094F","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Due to the presence of the stiff prosthetic stem fitted in the medullary canal during total his replacement, the surrounding cortex of the femur changes its density over time. This bone remodelling takes place with every type of total hip prosthesis; however, its intensity may vary between prostheses and patients. In the worst cases this process can lead to the late failure of the implant. To monitor such bone density evolution, we are developing a tailored Computer-aided Densitometric Image Analysis system (the major part of this our system uses an 8-bit commercial hardware with 256 levels of grey). The equivalent dynamic range of an X-ray picture is about 10 bits. In this paper we present a method to overcome these hardware limitations by improving the software. Using a double-exposure acquisition it is possible to build a 9-bit image that is good enough for most applications involving bone density measurement.

数字动态范围扩展在全髋关节置换术x线密度分析中的应用
由于在全置换术中植入髓管内的硬假体,股骨周围皮质的密度随着时间的推移而改变。这种骨重塑发生在每一种全髋关节假体中;然而,其强度可能因假体和患者而异。在最坏的情况下,这一过程可能导致植入物的晚期失效。为了监测这种骨密度的演变,我们正在开发一套量身定制的计算机辅助密度图像分析系统(该系统的主要部分使用8位商用硬件,灰度为256级)。x射线图像的等效动态范围约为10位。本文提出了一种通过改进软件来克服这些硬件限制的方法。使用双曝光采集,可以构建一个9位的图像,这对于大多数涉及骨密度测量的应用来说足够好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信