{"title":"Transient temperature responses of hydronic radiant floor heating system by different pipe embedding depth and water supply condition.","authors":"K S Chung, J Y Sohn, Y K Baik, J S Kang","doi":"10.2114/ahs1983.12.213","DOIUrl":null,"url":null,"abstract":"<p><p>\"Ondol\" is a Korean unique heating system. It is a specific radiant floor heating system using combustion heat of briquette or timber in Korea. Such traditional \"Ondol\" is changed to radiant heating system with pipe-coil embedded in the floor or slab. This study has contributed to the understandings of the transient behaviours of Ondol-heated floor panels and enclosure exposed to this type of heating system. The result is that the water supply temperature had a large effect on the rate of increase in floor surface and room air temperature. But, in spite of a higher water supply temperature, the heat flow rate was not increased considerably. The shallow pipe embedding depths, of course, result in a low heat flow rate.</p>","PeriodicalId":77409,"journal":{"name":"The Annals of physiological anthropology = Seiri Jinruigaku Kenkyukai kaishi","volume":"12 4","pages":"213-8"},"PeriodicalIF":0.0000,"publicationDate":"1993-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2114/ahs1983.12.213","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Annals of physiological anthropology = Seiri Jinruigaku Kenkyukai kaishi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2114/ahs1983.12.213","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
"Ondol" is a Korean unique heating system. It is a specific radiant floor heating system using combustion heat of briquette or timber in Korea. Such traditional "Ondol" is changed to radiant heating system with pipe-coil embedded in the floor or slab. This study has contributed to the understandings of the transient behaviours of Ondol-heated floor panels and enclosure exposed to this type of heating system. The result is that the water supply temperature had a large effect on the rate of increase in floor surface and room air temperature. But, in spite of a higher water supply temperature, the heat flow rate was not increased considerably. The shallow pipe embedding depths, of course, result in a low heat flow rate.