Validation and reproducibility of pressure-corrected aortic distensibility measurements using pulse-wave-velocity Doppler ultrasound

E.D. Lehmann , J.R. Parker , K.D. Hopkins , M.G. Taylor , R.G. Gosling
{"title":"Validation and reproducibility of pressure-corrected aortic distensibility measurements using pulse-wave-velocity Doppler ultrasound","authors":"E.D. Lehmann ,&nbsp;J.R. Parker ,&nbsp;K.D. Hopkins ,&nbsp;M.G. Taylor ,&nbsp;R.G. Gosling","doi":"10.1016/0141-5425(93)90118-I","DOIUrl":null,"url":null,"abstract":"<div><p>A non-invasive Doppler ultrasound technique is described for the assessment of aortic compliance based on the <em>in vivo</em> measurement of pulse wave velocity along the thoraco-abdominal aortic pathway. A structured protocol, which has been developed to improve the reproducibility of the technique, is validated. A method of correcting for the effect of non-chronic changes in blood pressure on arterial elasticity is considered and applied to compliance measurements performed on 66 normal, healthy volunteers. The results of a study to ascertain the overall reproducibility of the method are provided and problems associated with the technique are discussed. Medical disorders such as atherosclerosis, diabetes mellitus, familial hypercholesterolaemia and growth hormone deficiency have all been shown to affect arterial wall compliance. It is suggested that the <em>in vivo</em> measurement of pressure-corrected aortic distensibility may be a useful, non-invasive tool for assessing such patients' susceptibility to atheromatous arterial disease and for monitoring their response to therapy. Measurements in the aorta may be especially pertinent since the natural history of fatty streaks there tends to parallel that in coronary arteries thereby potentially affording a convenient surrogate estimate of coronary heart disease.</p></div>","PeriodicalId":75992,"journal":{"name":"Journal of biomedical engineering","volume":"15 3","pages":"Pages 221-228"},"PeriodicalIF":0.0000,"publicationDate":"1993-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0141-5425(93)90118-I","citationCount":"91","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/014154259390118I","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 91

Abstract

A non-invasive Doppler ultrasound technique is described for the assessment of aortic compliance based on the in vivo measurement of pulse wave velocity along the thoraco-abdominal aortic pathway. A structured protocol, which has been developed to improve the reproducibility of the technique, is validated. A method of correcting for the effect of non-chronic changes in blood pressure on arterial elasticity is considered and applied to compliance measurements performed on 66 normal, healthy volunteers. The results of a study to ascertain the overall reproducibility of the method are provided and problems associated with the technique are discussed. Medical disorders such as atherosclerosis, diabetes mellitus, familial hypercholesterolaemia and growth hormone deficiency have all been shown to affect arterial wall compliance. It is suggested that the in vivo measurement of pressure-corrected aortic distensibility may be a useful, non-invasive tool for assessing such patients' susceptibility to atheromatous arterial disease and for monitoring their response to therapy. Measurements in the aorta may be especially pertinent since the natural history of fatty streaks there tends to parallel that in coronary arteries thereby potentially affording a convenient surrogate estimate of coronary heart disease.

使用脉冲波速度多普勒超声测量压力校正主动脉扩张率的验证和可重复性
本文描述了一种无创多普勒超声技术,用于评估主动脉顺应性,该技术基于体内测量胸腹主动脉通道的脉冲波速度。为提高该技术的可重复性而开发的结构化协议得到了验证。本文考虑了一种校正非慢性血压变化对动脉弹性影响的方法,并将其应用于66名正常健康志愿者的依从性测量。提供了一项研究的结果,以确定该方法的总体再现性,并讨论了与该技术相关的问题。医学疾病如动脉粥样硬化、糖尿病、家族性高胆固醇血症和生长激素缺乏症都被证明会影响动脉壁的顺应性。这表明,在体内测量压力校正的主动脉扩张可能是一种有用的、无创的工具,用于评估这类患者对动脉粥样硬化疾病的易感性,并监测他们对治疗的反应。主动脉的测量可能特别相关,因为那里的脂肪条纹的自然历史倾向于与冠状动脉相似,因此可能为冠心病提供方便的替代估计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信