Development of an accurate portable recording peak-flow meter for the diagnosis of asthma

D.J. Hitchings , S.A. Dickinson , M.R. Miller , A.J. Fairfax
{"title":"Development of an accurate portable recording peak-flow meter for the diagnosis of asthma","authors":"D.J. Hitchings ,&nbsp;S.A. Dickinson ,&nbsp;M.R. Miller ,&nbsp;A.J. Fairfax","doi":"10.1016/0141-5425(93)90114-E","DOIUrl":null,"url":null,"abstract":"<div><p>This article describes the systematic design of an electronic recording peak expiratory flow (PEF) meter to provide accurate data for the diagnosis of occupational asthma. Traditional diagnosis of asthma relies on accurate data of PEF tests performed by the patients in their own homes and places of work. Unfortunately there are high error rates in data produced and recorded by the patient, most of these are transcription errors and some patients falsify their records. The PEF measurement itself is not effort independent, the data produced depending on the way in which the patient performs the test. Patients are taught how to perform the test giving maximal effort to the expiration being measured. If the measurement is performed incorrectly then errors will occur. Accurate data can be produced if an electronically recording PEF instrument is developed, thus freeing the patient from the task of recording the test data. It should also be capable of determining whether the PEF measurement has been correctly performed. A requirement specification for a recording PEF meter was produced. A commercially available electronic PEF meter was modified to provide the functions required for accurate serial recording of the measurements produced by the patients. This is now being used in three hospitals in the West Midlands for investigations into the diagnosis of occupational asthma. In investigating current methods of measuring PEF and other pulmonary quantities a greater understanding was obtained of the limitations of current methods of measurement, and quantities being measured. It is now possible to define the quantities that need to be measured for accurate pulmonary diagnosis and the requirements of future instrumentation to make these necessary measurements. We are now in the process of developing this new instrumentation.</p></div>","PeriodicalId":75992,"journal":{"name":"Journal of biomedical engineering","volume":"15 3","pages":"Pages 188-192"},"PeriodicalIF":0.0000,"publicationDate":"1993-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0141-5425(93)90114-E","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/014154259390114E","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This article describes the systematic design of an electronic recording peak expiratory flow (PEF) meter to provide accurate data for the diagnosis of occupational asthma. Traditional diagnosis of asthma relies on accurate data of PEF tests performed by the patients in their own homes and places of work. Unfortunately there are high error rates in data produced and recorded by the patient, most of these are transcription errors and some patients falsify their records. The PEF measurement itself is not effort independent, the data produced depending on the way in which the patient performs the test. Patients are taught how to perform the test giving maximal effort to the expiration being measured. If the measurement is performed incorrectly then errors will occur. Accurate data can be produced if an electronically recording PEF instrument is developed, thus freeing the patient from the task of recording the test data. It should also be capable of determining whether the PEF measurement has been correctly performed. A requirement specification for a recording PEF meter was produced. A commercially available electronic PEF meter was modified to provide the functions required for accurate serial recording of the measurements produced by the patients. This is now being used in three hospitals in the West Midlands for investigations into the diagnosis of occupational asthma. In investigating current methods of measuring PEF and other pulmonary quantities a greater understanding was obtained of the limitations of current methods of measurement, and quantities being measured. It is now possible to define the quantities that need to be measured for accurate pulmonary diagnosis and the requirements of future instrumentation to make these necessary measurements. We are now in the process of developing this new instrumentation.

一种用于哮喘诊断的精确便携式记录峰流量计的研制
本文介绍了一种电子记录呼气峰流量(PEF)仪的系统设计,为职业性哮喘的诊断提供准确的数据。传统的哮喘诊断依赖于患者在自己家中和工作场所进行的PEF测试的准确数据。不幸的是,患者产生和记录的数据错误率很高,其中大多数是转录错误,有些患者伪造他们的记录。PEF测量本身并不是与努力无关的,产生的数据取决于患者进行测试的方式。患者被教导如何进行测试,以最大的努力来测量到期。如果测量执行不正确,则会发生错误。如果开发了电子记录PEF仪器,则可以产生准确的数据,从而使患者从记录测试数据的任务中解脱出来。它还应该能够确定PEF测量是否已正确执行。产生了记录PEF计的需求规范。对市售的电子PEF计进行了修改,以提供对患者产生的测量结果进行精确串行记录所需的功能。目前,西米德兰兹郡的三家医院正在使用这种仪器对职业性哮喘的诊断进行调查。在研究当前测量PEF和其他肺量的方法时,对当前测量方法和被测量量的局限性有了更深入的了解。现在可以确定准确肺部诊断需要测量的量,以及未来仪器进行这些必要测量的要求。我们现在正在开发这种新仪器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信