Precision and accuracy of bone landmarks in characterizing hand and wrist position

C.F. Small, D.R. Pichora, J.T. Bryant, P.M. Griffiths
{"title":"Precision and accuracy of bone landmarks in characterizing hand and wrist position","authors":"C.F. Small,&nbsp;D.R. Pichora,&nbsp;J.T. Bryant,&nbsp;P.M. Griffiths","doi":"10.1016/0141-5425(93)90073-8","DOIUrl":null,"url":null,"abstract":"<div><p>Characterization of the motion of the hand and wrist requires reference to the underlying bones which, for three-dimensional analyses, are assumed to be rigid bodies. Stereoradiogrammetric techniques involving the identification of prominent bone landmarks have been used as the standard against which surface markers used for <em>in vivo</em> testing have been evaluated. The precision and accuracy with which the 3D positions of bone landmarks in the hand and wrist could be determined was evaluated in a small inter-observer and inter-cadaver study and compared to the precision and accuracy with which implanted lead markers could be located. A subset of landmarks suitable for evaluating wrist and metacarpal-phalangeal joint motion was identified; the mean precison for identifying these points was better than 1.1 mm in all hand positions with a mean inter-observer accuracy of 2.3 mm. These values show that the average uncertainty in locating bone landmarks is at best roughly twice that for implanted markers.</p></div>","PeriodicalId":75992,"journal":{"name":"Journal of biomedical engineering","volume":"15 5","pages":"Pages 371-378"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0141-5425(93)90073-8","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical engineering","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0141542593900738","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

Abstract

Characterization of the motion of the hand and wrist requires reference to the underlying bones which, for three-dimensional analyses, are assumed to be rigid bodies. Stereoradiogrammetric techniques involving the identification of prominent bone landmarks have been used as the standard against which surface markers used for in vivo testing have been evaluated. The precision and accuracy with which the 3D positions of bone landmarks in the hand and wrist could be determined was evaluated in a small inter-observer and inter-cadaver study and compared to the precision and accuracy with which implanted lead markers could be located. A subset of landmarks suitable for evaluating wrist and metacarpal-phalangeal joint motion was identified; the mean precison for identifying these points was better than 1.1 mm in all hand positions with a mean inter-observer accuracy of 2.3 mm. These values show that the average uncertainty in locating bone landmarks is at best roughly twice that for implanted markers.

精确和准确的骨标记表征手和手腕的位置
描述手和手腕的运动需要参考下面的骨骼,对于三维分析,这些骨骼被认为是刚体。涉及识别突出骨标记的立体放射测量技术已被用作评估用于体内测试的表面标记物的标准。在一项小型的观察者之间和尸体之间的研究中,评估了手腕骨标记物3D位置的精度和准确性,并与植入的铅标记物定位的精度和准确性进行比较。确定了适合评估腕关节和掌指关节运动的标志子集;在所有手位中,识别这些点的平均精度优于1.1 mm,观察者间的平均精度为2.3 mm。这些值表明,定位骨标记的平均不确定性最多是植入标记的两倍左右。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信