Characterization of drug disposition and dosing using bioelectrical impedance.

Medical progress through technology Pub Date : 1993-01-01
B J Zarowitz, E L Peterson, S Robert
{"title":"Characterization of drug disposition and dosing using bioelectrical impedance.","authors":"B J Zarowitz,&nbsp;E L Peterson,&nbsp;S Robert","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Bioelectrical impedance analysis (BIA) yields accurate, safe and non-invasive estimates of body composition in humans. Pharmacokinetic characterization of drugs represents the body as a series of non-physiologic compartments. We evaluated the utility of BIA in the pharmacokinetic characterization and dosing of water soluble drugs. Serial serum concentrations of gentamicin (G) in 30 hospitalized adults, and theophylline (T), in 15 normal adult males were obtained over a dosing interval after an 8h fast, and analyzed in duplicate by enzyme-mediated immunoassay technique. BIA was performed serially in duplicate during the same time period using a fixed frequency (50kHz, 800 microA) current-injection 4-electrode plethysmograph. Multiple regression techniques were used to develop descriptive models of pharmacokinetic parameters which yielded equations with p-values < 0.03 and coefficients of variation < 20% accounting for > 85% of the pharmacokinetic variability. The G models were then tested in 20 critically ill adults at steady state by serum concentration measurement (criterion standard) and BIA. BIA predictive equations yielded pharmacokinetic parameters not different (by paired t-tests) than those derived by serum concentration measurement. While BIA is an innovative approach to the non-invasive characterization water soluble drugs, further testing with variable frequency BIA under perturbed conditions is warranted.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"19 4","pages":"193-8"},"PeriodicalIF":0.0000,"publicationDate":"1993-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical progress through technology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Bioelectrical impedance analysis (BIA) yields accurate, safe and non-invasive estimates of body composition in humans. Pharmacokinetic characterization of drugs represents the body as a series of non-physiologic compartments. We evaluated the utility of BIA in the pharmacokinetic characterization and dosing of water soluble drugs. Serial serum concentrations of gentamicin (G) in 30 hospitalized adults, and theophylline (T), in 15 normal adult males were obtained over a dosing interval after an 8h fast, and analyzed in duplicate by enzyme-mediated immunoassay technique. BIA was performed serially in duplicate during the same time period using a fixed frequency (50kHz, 800 microA) current-injection 4-electrode plethysmograph. Multiple regression techniques were used to develop descriptive models of pharmacokinetic parameters which yielded equations with p-values < 0.03 and coefficients of variation < 20% accounting for > 85% of the pharmacokinetic variability. The G models were then tested in 20 critically ill adults at steady state by serum concentration measurement (criterion standard) and BIA. BIA predictive equations yielded pharmacokinetic parameters not different (by paired t-tests) than those derived by serum concentration measurement. While BIA is an innovative approach to the non-invasive characterization water soluble drugs, further testing with variable frequency BIA under perturbed conditions is warranted.

利用生物电阻抗表征药物处置和给药。
生物电阻抗分析(BIA)可以准确、安全、无创地估计人体成分。药物的药代动力学表征将机体表征为一系列非生理性隔间。我们评估了BIA在水溶性药物的药代动力学表征和给药方面的效用。采用酶介导免疫分析法对30例住院成人患者和15例正常成年男性患者的庆大霉素(G)和茶碱(T)的连续给药间隔进行分析。在同一时间段内,使用固定频率(50kHz, 800 microA)电流注入4电极体积脉搏仪连续重复进行BIA。采用多元回归技术建立药代动力学参数描述模型,得到p值< 0.03,变异系数< 20%占药代动力学变异性的> 85%的方程。用G模型对20例危重症成人进行稳态血药浓度测定(标准标准)和BIA检测。BIA预测方程得出的药代动力学参数(通过配对t检验)与通过血清浓度测量得出的药代动力学参数没有差异。虽然BIA是一种创新的非侵入性表征水溶性药物的方法,但在扰动条件下进行变频BIA的进一步测试是有必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书