Usefulness and limitations of the positive protosystolic peak of coronary arterial blood flow as an index of epicardial arterial compliance.

Cardioscience Pub Date : 1994-06-01
G Verlato, R Poltronieri
{"title":"Usefulness and limitations of the positive protosystolic peak of coronary arterial blood flow as an index of epicardial arterial compliance.","authors":"G Verlato,&nbsp;R Poltronieri","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of the study was to investigate the physiological meaning of the positive peak which appears at the onset of ventricular ejection on traces of blood flow in the left coronary artery. It was proposed that the protosystolic peak could represent systolic charging of epicardial coronary arterial compliance, i.e. the compliance which is not squeezed by myocardial contraction and which resides in superficial coronary arteries. To verify this hypothesis, blood flow was recorded from the left circumflex coronary artery in five anesthetized open-chest dogs and the protosystolic peak was identified by visual analysis or on the basis of zero-crossing of the first derivative. An index of epicardial compliance (delta V/delta P) was derived by dividing the peak area (delta V) by the aortic pulse pressure (delta P). Under basal conditions, the estimate of epicardial compliance, amounting to 0.271 +/- 0.149 x 10(-3) ml/mmHg (2.04 +/- 1.12 x 10(-12) m4s2kg-1; mean +/- SD), fell in the lower part of the range of values found by different authors and increased during hemorrhagic hypotension, due to nonlinearities of compliance in general. Similar values of epicardial compliance were obtained when a lumped resistance-capacitance parallel model was fitted to systolic coronary blood flow. Unexpectedly, however, the protosystolic peak was greatly decreased during coronary reactive hyperemia. We conclude that the protosystolic peak can be used as an index of epicardial compliance, but only at basal coronary vasomotor tone.</p>","PeriodicalId":9629,"journal":{"name":"Cardioscience","volume":"5 2","pages":"87-94"},"PeriodicalIF":0.0000,"publicationDate":"1994-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardioscience","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of the study was to investigate the physiological meaning of the positive peak which appears at the onset of ventricular ejection on traces of blood flow in the left coronary artery. It was proposed that the protosystolic peak could represent systolic charging of epicardial coronary arterial compliance, i.e. the compliance which is not squeezed by myocardial contraction and which resides in superficial coronary arteries. To verify this hypothesis, blood flow was recorded from the left circumflex coronary artery in five anesthetized open-chest dogs and the protosystolic peak was identified by visual analysis or on the basis of zero-crossing of the first derivative. An index of epicardial compliance (delta V/delta P) was derived by dividing the peak area (delta V) by the aortic pulse pressure (delta P). Under basal conditions, the estimate of epicardial compliance, amounting to 0.271 +/- 0.149 x 10(-3) ml/mmHg (2.04 +/- 1.12 x 10(-12) m4s2kg-1; mean +/- SD), fell in the lower part of the range of values found by different authors and increased during hemorrhagic hypotension, due to nonlinearities of compliance in general. Similar values of epicardial compliance were obtained when a lumped resistance-capacitance parallel model was fitted to systolic coronary blood flow. Unexpectedly, however, the protosystolic peak was greatly decreased during coronary reactive hyperemia. We conclude that the protosystolic peak can be used as an index of epicardial compliance, but only at basal coronary vasomotor tone.

冠状动脉血流原收缩阳性峰值作为心外膜动脉顺应性指标的有效性和局限性。
该研究的目的是研究阳性峰的生理意义,它出现在左冠状动脉血流痕迹的心室射血的开始。提出原收缩期峰值可代表心外膜冠状动脉顺应性的收缩期充电,即不受心肌收缩挤压、位于冠状动脉浅部的顺应性。为了验证这一假设,我们记录了5只麻醉开胸犬左旋冠状动脉的血流,并通过视觉分析或基于一阶导数的零交叉来识别原始收缩峰值。心外膜依从性指数(δ V/ δ P)由峰值面积(δ V)除以主动脉脉压(δ P)得出。在基础条件下,心外膜依从性的估计值为0.271 +/- 0.149 × 10(-3) ml/mmHg (2.04 +/- 1.12 × 10(-12) m4s2kg-1;平均+/- SD),由于依从性的非线性,在不同作者发现的值范围的下半部分下降,并且在出血性低血压期间增加。当一个集总电阻-电容平行模型拟合收缩期冠状动脉血流时,心外膜顺应性也得到了类似的值。然而,出乎意料的是,在冠状动脉反应性充血期间,原收缩峰值大大降低。我们得出结论,原收缩期峰值可作为心外膜顺应性的指标,但仅适用于基底冠状动脉血管舒缩张力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信