Comparison of astigmatic axis in the seated and supine positions.

E M Smith, J H Talamo, K K Assil, D E Petashnick
{"title":"Comparison of astigmatic axis in the seated and supine positions.","authors":"E M Smith,&nbsp;J H Talamo,&nbsp;K K Assil,&nbsp;D E Petashnick","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Refractive error is assessed in the seated position while keratorefractive procedures are performed in the supine position. Since position-induced ocular torsion could yield suboptimal results from improper axis alignment, this study was undertaken to ascertain whether ocular cyclotorsion occurs when a subject moves from a seated to supine position.</p><p><strong>Methods: </strong>Fifty eyes of 29 subjects with refractive cylinder greater than 0.50 diopters were enrolled. Refraction was done with a phoropter and the correction was placed in a trial frame using plus cylinder. Astigmatic axis was determined in the seated and supine positions for 32 eyes by utilizing the \"rocking the cylinder\" technique and for 32 eyes using the Jackson cross cylinder. Both techniques were used for 14 eyes.</p><p><strong>Results: </strong>No statistically-significant difference for cylinder axis measured in the seated versus supine position was observed using the rocking the cylinder (4.3 degrees standard deviation [SD], 3.5 degrees, range 0 degrees to 13 degrees, p = NS) or the Jackson cross cylinder methods (2.3 degrees, SD, 1.9 degrees, range 0 degrees to 7 degrees, p = NS). Approximately 25% of eyes had a change in axis of 7 degrees to 16 degrees.</p><p><strong>Conclusions: </strong>These data suggest that the cylinder axis does not change significantly or predictably when most subjects move from the seated to supine position. The Jackson cross cylinder method seems more accurate and reproducible than the rocking the cylinder technique in determination of astigmatic axis under these circumstances.</p>","PeriodicalId":79348,"journal":{"name":"Journal of refractive and corneal surgery","volume":"10 6","pages":"615-20"},"PeriodicalIF":0.0000,"publicationDate":"1994-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive and corneal surgery","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Refractive error is assessed in the seated position while keratorefractive procedures are performed in the supine position. Since position-induced ocular torsion could yield suboptimal results from improper axis alignment, this study was undertaken to ascertain whether ocular cyclotorsion occurs when a subject moves from a seated to supine position.

Methods: Fifty eyes of 29 subjects with refractive cylinder greater than 0.50 diopters were enrolled. Refraction was done with a phoropter and the correction was placed in a trial frame using plus cylinder. Astigmatic axis was determined in the seated and supine positions for 32 eyes by utilizing the "rocking the cylinder" technique and for 32 eyes using the Jackson cross cylinder. Both techniques were used for 14 eyes.

Results: No statistically-significant difference for cylinder axis measured in the seated versus supine position was observed using the rocking the cylinder (4.3 degrees standard deviation [SD], 3.5 degrees, range 0 degrees to 13 degrees, p = NS) or the Jackson cross cylinder methods (2.3 degrees, SD, 1.9 degrees, range 0 degrees to 7 degrees, p = NS). Approximately 25% of eyes had a change in axis of 7 degrees to 16 degrees.

Conclusions: These data suggest that the cylinder axis does not change significantly or predictably when most subjects move from the seated to supine position. The Jackson cross cylinder method seems more accurate and reproducible than the rocking the cylinder technique in determination of astigmatic axis under these circumstances.

坐位与仰卧位的像散轴比较。
背景:屈光不正评估在坐姿,而角膜屈光手术在仰卧位进行。由于体位引起的眼扭转可能由于不正确的轴对齐而产生不理想的结果,因此本研究旨在确定当受试者从坐姿移动到仰卧位时是否会发生眼旋扭转。方法:选取29例屈光圆柱体大于0.50屈光度的患者50只眼。折射是用照相机完成的,校正是用正圆柱体放在一个试验框架中。32眼采用“摇柱法”确定坐位和仰卧位的散光轴,32眼采用Jackson十字柱法。两种技术均用于14只眼睛。结果:采用摇柱法(4.3度标准差[SD], 3.5度,范围0度至13度,p = NS)和Jackson交叉柱法(2.3度,SD, 1.9度,范围0度至7度,p = NS),坐位与仰卧位测量的柱轴无统计学差异。大约25%的眼睛的眼轴发生了7到16度的变化。结论:这些数据表明,当大多数受试者从坐位移动到仰卧位时,椎体轴不会发生显著或可预测的变化。在这种情况下,Jackson交叉柱法比摇柱法测定像散轴更准确,重现性更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信