Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate.

Medical progress through technology Pub Date : 1995-05-01
K Nishida, M Sakakida, K Ichinose, T Uemura, M Uehara, K Kajiwara, T Miyata, M Shichiri, K Ishihara, N Nakabayashi
{"title":"Development of a ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate.","authors":"K Nishida,&nbsp;M Sakakida,&nbsp;K Ichinose,&nbsp;T Uemura,&nbsp;M Uehara,&nbsp;K Kajiwara,&nbsp;T Miyata,&nbsp;M Shichiri,&nbsp;K Ishihara,&nbsp;N Nakabayashi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To prepare the long-life and stable glucose sensor, we developed the ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate (MPC-co-BMA) membrane. In this membrane, the hydrophilic phosphorylcholine chains were grafted on the hydrophobic polymer surface. 1. The poly(MPC-co-BMA) membrane inhibited platelet activation and protein adhesion on the surface, showing excellent biocompatibility. These results suggested that the hydrophilic phospholipids chains might have the potential for suppressing activation and adsorption of biochemical molecules. 2. The ferrocene-mediated needle-type glucose sensor covered with poly(MPC-co-BMA) membrane achieved excellent results in vitro. Subcutaneous tissue glucose concentrations were measured in a wide range from 1.7 to more than 16.7 mmol/l. The correlation between subcutaneous tissue (Y) and blood (X) glucose concentrations was Y = 1.04X + 0.12 (r = 0.98). The subcutaneous tissue glucose concentrations could be monitored precisely for 7 days without any in vivo calibrations, and for 14 days by introducing in vivo calibrations. We therefore conclude that this sensor is stable and reliable, as compared to any other glucose sensors we developed.</p>","PeriodicalId":76136,"journal":{"name":"Medical progress through technology","volume":"21 2","pages":"91-103"},"PeriodicalIF":0.0000,"publicationDate":"1995-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical progress through technology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To prepare the long-life and stable glucose sensor, we developed the ferrocene-mediated needle-type glucose sensor covered with newly designed biocompatible membrane, 2-methacryloyloxyethyl phosphorylcholine-co-n-butyl methacrylate (MPC-co-BMA) membrane. In this membrane, the hydrophilic phosphorylcholine chains were grafted on the hydrophobic polymer surface. 1. The poly(MPC-co-BMA) membrane inhibited platelet activation and protein adhesion on the surface, showing excellent biocompatibility. These results suggested that the hydrophilic phospholipids chains might have the potential for suppressing activation and adsorption of biochemical molecules. 2. The ferrocene-mediated needle-type glucose sensor covered with poly(MPC-co-BMA) membrane achieved excellent results in vitro. Subcutaneous tissue glucose concentrations were measured in a wide range from 1.7 to more than 16.7 mmol/l. The correlation between subcutaneous tissue (Y) and blood (X) glucose concentrations was Y = 1.04X + 0.12 (r = 0.98). The subcutaneous tissue glucose concentrations could be monitored precisely for 7 days without any in vivo calibrations, and for 14 days by introducing in vivo calibrations. We therefore conclude that this sensor is stable and reliable, as compared to any other glucose sensors we developed.

二茂铁介导的针型葡萄糖传感器的研制- 2-甲基丙烯酰氧乙基磷酸胆碱-甲基丙烯酸正丁酯生物相容性膜
为了制备长寿命稳定的葡萄糖传感器,我们研制了二茂铁介导的针状葡萄糖传感器,并在其表面覆盖了一种新型生物相容性膜——2-甲基丙烯酰氧乙基磷酸胆碱-甲基丙烯酸正丁酯(MPC-co-BMA)膜。在该膜中,亲水性磷胆碱链被接枝到疏水性聚合物表面。1. 聚(MPC-co-BMA)膜抑制血小板活化和表面蛋白粘附,具有良好的生物相容性。这些结果表明亲水性磷脂链可能具有抑制生化分子活化和吸附的潜力。2. 二茂铁介导的针式葡萄糖传感器在体外获得了良好的效果。皮下组织葡萄糖浓度测量范围从1.7到超过16.7 mmol/l。皮下组织(Y)与血液(X)葡萄糖浓度的相关性为Y = 1.04X + 0.12 (r = 0.98)。在没有任何体内校准的情况下,可以精确监测7天的皮下组织葡萄糖浓度,在引入体内校准后可以监测14天。因此,我们得出结论,与我们开发的任何其他葡萄糖传感器相比,该传感器稳定可靠。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书