[Optimization of the immunoelectrophoresis technic (western blot) for the confirmation of human immunodeficiency virus infection (HIV) in Panama].

Revista medica de Panama Pub Date : 1995-01-01
J M Pascale, E de Austin, N O de Moreno, C Ledezma, E de Márquez, R Blanco, E Quiroz, J Calzada, A R Vincensini, M C de Martin
{"title":"[Optimization of the immunoelectrophoresis technic (western blot) for the confirmation of human immunodeficiency virus infection (HIV) in Panama].","authors":"J M Pascale,&nbsp;E de Austin,&nbsp;N O de Moreno,&nbsp;C Ledezma,&nbsp;E de Márquez,&nbsp;R Blanco,&nbsp;E Quiroz,&nbsp;J Calzada,&nbsp;A R Vincensini,&nbsp;M C de Martin","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this study is to report the results of the authors' investigation to apply the western blot technique (WB UP-LCS) in the diagnosis of human immunodeficiency virus type 1 (HIV-1) infection. To do this, the authors separated the proteins of the HIV-1 virus by electrophoresis, based on their molecular weight, in poliacilamide gel with SDS (SDS-PAGE) during 3 hours at 200 volts. Then they electrotransferred these proteins to nitrocellulose paper during four hours at 200 milliamperes, with the aid of external cooling. The nitrocellulose strips were evaluated considering the incubation time (1 and 16 hours), two conjugates (human anti IgG with Peroxidase and human anti IgG Biotin plus Streptatividine with Peroxidase) and two dilutions of the patients' sera (1/50 and 1/100). Based on their results the Authors conclude that, in the first place, the optimal conditions for the test include a dilution of 1/100 of the patients serum, incubation of the serum for 16 hours and the use of the conjugate of anti human IgG with Biotin and Streptavidine with Peroxidase; secondary, that the immunologic reactivity against proteins p24 and gp 160/120 is the most important diagnostic criterion for the confirmation of infection with HIV-1 and that they obtained a diagnostic correlation of 100% at a cost which was 5 to 7 times less than that of the commercial system.</p>","PeriodicalId":21235,"journal":{"name":"Revista medica de Panama","volume":"20 1-2","pages":"58-64"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista medica de Panama","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this study is to report the results of the authors' investigation to apply the western blot technique (WB UP-LCS) in the diagnosis of human immunodeficiency virus type 1 (HIV-1) infection. To do this, the authors separated the proteins of the HIV-1 virus by electrophoresis, based on their molecular weight, in poliacilamide gel with SDS (SDS-PAGE) during 3 hours at 200 volts. Then they electrotransferred these proteins to nitrocellulose paper during four hours at 200 milliamperes, with the aid of external cooling. The nitrocellulose strips were evaluated considering the incubation time (1 and 16 hours), two conjugates (human anti IgG with Peroxidase and human anti IgG Biotin plus Streptatividine with Peroxidase) and two dilutions of the patients' sera (1/50 and 1/100). Based on their results the Authors conclude that, in the first place, the optimal conditions for the test include a dilution of 1/100 of the patients serum, incubation of the serum for 16 hours and the use of the conjugate of anti human IgG with Biotin and Streptavidine with Peroxidase; secondary, that the immunologic reactivity against proteins p24 and gp 160/120 is the most important diagnostic criterion for the confirmation of infection with HIV-1 and that they obtained a diagnostic correlation of 100% at a cost which was 5 to 7 times less than that of the commercial system.

【巴拿马人免疫缺陷病毒感染(HIV)确认免疫电泳技术(western blot)的优化】。
本研究的目的是报告作者应用western blot技术(WB UP-LCS)诊断人类免疫缺陷病毒1型(HIV-1)感染的研究结果。为了做到这一点,作者根据其分子量,在含有SDS (SDS- page)的poliacilamide凝胶中,在200伏下持续3小时,通过电泳分离HIV-1病毒的蛋白质。然后,在外部冷却的帮助下,在200毫安的条件下,他们在四小时内将这些蛋白质电转移到硝化纤维素纸上。考虑孵育时间(1小时和16小时)、两种结合物(人抗IgG -过氧化物酶和人抗IgG -生物素-过氧化物酶链球菌活络素)和患者血清的两种稀释度(1/50和1/100),对硝化纤维素试纸条进行评价。根据他们的结果,作者得出结论,首先,测试的最佳条件包括:将患者血清稀释1/100,血清孵育16小时,并使用抗人IgG与生物素和链霉亲和定与过氧化物酶的偶联物;其次,对蛋白p24和gp 160/120的免疫反应性是确认HIV-1感染的最重要的诊断标准,它们的诊断相关性为100%,成本比商业系统低5 - 7倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信