[Transcutaneous measurement of pO2.(author's transl)].

B Dautzenberg, H Carter, C Sors
{"title":"[Transcutaneous measurement of pO2.(author's transl)].","authors":"B Dautzenberg,&nbsp;H Carter,&nbsp;C Sors","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An apparatus which allowed the measurement of transcutaneous paO2 (tcpO2) was tested on adults in an intensive care unit. The correlation between tcpO2 and blood paO2 was satisfactory (r = 0.91, n = 111), but the slope of the regression line was variable from one subject to another. On account of the poor transfer of information from the arterial blood to the skin surface, this slope could be very flat (0.43 in one of the subjects in the study). The response time of the apparatus was very short and allowed a study of the effect on the individual of variations in FIO2. The equipment appears useful for continuous non invasive monitoring of the progress of the pO2, but it cannot directly give the true value of the paO2.</p>","PeriodicalId":76480,"journal":{"name":"Revue francaise des maladies respiratoires","volume":"9 4","pages":"327-35"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revue francaise des maladies respiratoires","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An apparatus which allowed the measurement of transcutaneous paO2 (tcpO2) was tested on adults in an intensive care unit. The correlation between tcpO2 and blood paO2 was satisfactory (r = 0.91, n = 111), but the slope of the regression line was variable from one subject to another. On account of the poor transfer of information from the arterial blood to the skin surface, this slope could be very flat (0.43 in one of the subjects in the study). The response time of the apparatus was very short and allowed a study of the effect on the individual of variations in FIO2. The equipment appears useful for continuous non invasive monitoring of the progress of the pO2, but it cannot directly give the true value of the paO2.

经皮测量pO2。(作者的transl)]。
在重症监护病房的成年人身上测试了一种允许经皮paO2 (tcpO2)测量的仪器。tcpO2与血paO2的相关性令人满意(r = 0.91, n = 111),但不同受试者的回归线斜率不同。由于从动脉血到皮肤表面的信息传递较差,这个斜率可能非常平坦(在研究中的一个受试者中为0.43)。该仪器的响应时间非常短,可以研究FIO2变化对个体的影响。该设备可用于连续无创监测pO2的进展,但不能直接给出paO2的真实值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信