Transcutaneous oxygen monitoring from the fetus during labor: a study of the TcPO2 levels and comparison of two electrode application techniques.

Biotelemetry and patient monitoring Pub Date : 1982-01-01
O Löfgren
{"title":"Transcutaneous oxygen monitoring from the fetus during labor: a study of the TcPO2 levels and comparison of two electrode application techniques.","authors":"O Löfgren","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The technique for transcutaneous oxygen (TcPO2) monitoring is now routine in neonatal intensive care. The method was presented earlier as a potential tool for fetal surveillance during labor. The current study reports on two techniques generally used for the application of the electrode to the fetus. The application of the electrode by a suction instrument does not influence the TcPO2 level recorded and the use of this technique is very simple. However, the main disadvantage of the suction instrument is that the electrode is easily detached. Application of the electrode by glue is technically a little more difficult but has the advantage of being much more efficient. If the criteria for a reliable recording presented in the study are fulfilled, the technique may be used as an additional parameter to diagnose true fetal hypoxemia.</p>","PeriodicalId":75603,"journal":{"name":"Biotelemetry and patient monitoring","volume":"9 3","pages":"166-74"},"PeriodicalIF":0.0000,"publicationDate":"1982-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry and patient monitoring","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The technique for transcutaneous oxygen (TcPO2) monitoring is now routine in neonatal intensive care. The method was presented earlier as a potential tool for fetal surveillance during labor. The current study reports on two techniques generally used for the application of the electrode to the fetus. The application of the electrode by a suction instrument does not influence the TcPO2 level recorded and the use of this technique is very simple. However, the main disadvantage of the suction instrument is that the electrode is easily detached. Application of the electrode by glue is technically a little more difficult but has the advantage of being much more efficient. If the criteria for a reliable recording presented in the study are fulfilled, the technique may be used as an additional parameter to diagnose true fetal hypoxemia.

产程中胎儿经皮氧监测:TcPO2水平的研究和两种电极应用技术的比较。
经皮氧(TcPO2)监测技术现已成为新生儿重症监护的常规技术。该方法在分娩过程中作为胎儿监测的潜在工具提出。目前的研究报告了两种通常用于胎儿电极应用的技术。吸吸仪电极的应用不影响所记录的TcPO2水平,该技术的使用非常简单。然而,吸吸仪的主要缺点是电极容易脱落。通过胶水应用电极在技术上有点困难,但具有效率更高的优点。如果研究中提出的可靠记录的标准得到满足,该技术可以用作诊断真正的胎儿低氧血症的附加参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信