[Total thoracic compliance. Determination by calculator and comparison with values obtained with the syringe method (author's transl)].

Anesthesie, analgesie, reanimation Pub Date : 1981-01-01
C Martin, P Rignault, A Chevalier, J P Auffray, F Gouin
{"title":"[Total thoracic compliance. Determination by calculator and comparison with values obtained with the syringe method (author's transl)].","authors":"C Martin,&nbsp;P Rignault,&nbsp;A Chevalier,&nbsp;J P Auffray,&nbsp;F Gouin","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The performance of a calculator was studied on 19 patients requiring therapy with mechanical ventilation. Values of total compliance displayed by this calculator device were compared with values obtained with the syringe method. The determination of compliance were made at a series of values for Tidal volume (T. V.): 3, 4, 5, 6, 8, 10, 12, 15, 18, 20, 23 and 26 ml.kg-1. Measurements were performed while patients were paralysed by pancuronium bromide. In each patient the calculator device displayed values that correlate closely with the value obtained by the syringe method. Compliance increased between 3 and 26 ml.kg-1 of T. D. Between 4 and 15 ml.kg-1 of TD the changes of compliance were nearly identical whatever the method of measurement used. The calculator can be used for reliable monitoring or recordings of total compliance.</p>","PeriodicalId":7785,"journal":{"name":"Anesthesie, analgesie, reanimation","volume":"38 11-12","pages":"603-8"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anesthesie, analgesie, reanimation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The performance of a calculator was studied on 19 patients requiring therapy with mechanical ventilation. Values of total compliance displayed by this calculator device were compared with values obtained with the syringe method. The determination of compliance were made at a series of values for Tidal volume (T. V.): 3, 4, 5, 6, 8, 10, 12, 15, 18, 20, 23 and 26 ml.kg-1. Measurements were performed while patients were paralysed by pancuronium bromide. In each patient the calculator device displayed values that correlate closely with the value obtained by the syringe method. Compliance increased between 3 and 26 ml.kg-1 of T. D. Between 4 and 15 ml.kg-1 of TD the changes of compliance were nearly identical whatever the method of measurement used. The calculator can be used for reliable monitoring or recordings of total compliance.

[全胸廓顺应性。用计算器测定并与注射器法比较[作者简介]。
在19例需要机械通气治疗的患者中研究了计算器的性能。将该计算器装置显示的总顺应性值与注射器法获得的值进行比较。在潮汐容积(t.v.) 3、4、5、6、8、10、12、15、18、20、23和26 ml.kg-1的一系列值下测定顺应性。测量是在病人被泮库溴铵麻痹时进行的。在每个患者中,计算器装置显示的值与注射器法获得的值密切相关。服药量在3 ~ 26 ml.kg-1之间增加,服药量在4 ~ 15 ml.kg-1之间,无论采用何种测量方法,服药量的变化几乎相同。该计算器可用于可靠的监测或记录总的遵守情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信