[Studies on the distortion of the cast crown by measuring volume change (author's transl)].

H Arikawa, K Jyoshin, S Nakazawa
{"title":"[Studies on the distortion of the cast crown by measuring volume change (author's transl)].","authors":"H Arikawa,&nbsp;K Jyoshin,&nbsp;S Nakazawa","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We made experimental cast crowns under various casting conditions, and measured their dimensional change of inner cervical margin and volume change compared with wax patterns. The relation between percentage of linear expansion (alpha) and percentage of cubic expansion (beta) of matter is beta not equal to 3alpha. When investment mold and cast metal equally expand or contract in all direction, the relation between the dimensional change (=alpha) and the volume change (=beta) of the cast crown must obey this expression beta not equal to 3alpha. When the relation between alpha and beta of the cast crown is not beta not equal to 3alpha, we consider the cast has distortion. Casting conditions were fifteen kinds by changing investment, casting method, linning material and mold temperature. The following results were obtained. 1) Placing wet asbestos liner, dimension was larger than its pattern. But, contraction of volume was great. 2) Placing kaowool liner and asbestos liner coated with vaseline contraction of volume was improved. 3) In case of ringless casting method, the cast crown gave best fit to metal die, and distortion was very small. 4) Judging from these results, hygroscopic expansion of investment by wet asbestos liner made volume contracts, and made the cast crown distort. 5) In case of casting at low temperature ceravest mold (150 degree C), dimension was as large as casting at high temperature mold (700 degree C). But, the lower the mold temperature, the larger the contraction of volume. Therefore, the cast crown fitted metal die, but had large distortion.</p>","PeriodicalId":76541,"journal":{"name":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","volume":"22 58","pages":"114-8"},"PeriodicalIF":0.0000,"publicationDate":"1981-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Shika rikogaku zasshi. Journal of the Japan Society for Dental Apparatus and Materials","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We made experimental cast crowns under various casting conditions, and measured their dimensional change of inner cervical margin and volume change compared with wax patterns. The relation between percentage of linear expansion (alpha) and percentage of cubic expansion (beta) of matter is beta not equal to 3alpha. When investment mold and cast metal equally expand or contract in all direction, the relation between the dimensional change (=alpha) and the volume change (=beta) of the cast crown must obey this expression beta not equal to 3alpha. When the relation between alpha and beta of the cast crown is not beta not equal to 3alpha, we consider the cast has distortion. Casting conditions were fifteen kinds by changing investment, casting method, linning material and mold temperature. The following results were obtained. 1) Placing wet asbestos liner, dimension was larger than its pattern. But, contraction of volume was great. 2) Placing kaowool liner and asbestos liner coated with vaseline contraction of volume was improved. 3) In case of ringless casting method, the cast crown gave best fit to metal die, and distortion was very small. 4) Judging from these results, hygroscopic expansion of investment by wet asbestos liner made volume contracts, and made the cast crown distort. 5) In case of casting at low temperature ceravest mold (150 degree C), dimension was as large as casting at high temperature mold (700 degree C). But, the lower the mold temperature, the larger the contraction of volume. Therefore, the cast crown fitted metal die, but had large distortion.

[用体积变化测量铸冠变形的研究[作者简介]。
我们制作了不同铸造条件下的实验铸造冠,并测量了其颈内缘的尺寸变化和与蜡模的体积变化。物质的线性膨胀百分比(α)和立方膨胀百分比(β)之间的关系是β不等于3 α。当熔模与铸模在各方向均匀膨胀或收缩时,铸冠的尺寸变化(=alpha)与体积变化(=beta)之间的关系必须服从这个表达式beta不等于3alpha。当铸型冠的α与β的关系不等于β不等于3 α时,我们认为铸型存在畸变。通过改变熔模、铸造方法、衬里材料和模具温度,可以得到15种不同的铸造条件。得到了以下结果:1)放置湿石棉衬垫,尺寸大于其图案。但是,体积收缩很大。2)采用高岭土衬里和涂有凡士林的石棉衬里,改善了体积收缩。3)采用无环铸造法时,铸冠与金属模具贴合效果最好,变形很小。4)从这些结果来看,湿石棉衬垫对投资板的吸湿膨胀使其体积收缩,使铸冠变形。5)在低温模(150℃)下铸造,尺寸与高温模(700℃)下铸造一样大,但模温越低,体积收缩越大。因此,铸冠贴合金属模具,但变形大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信