Linearity law reexamined for flicker photometry by the summation-index method.

M Ikeda
{"title":"Linearity law reexamined for flicker photometry by the summation-index method.","authors":"M Ikeda","doi":"10.1364/josa.73.001055","DOIUrl":null,"url":null,"abstract":"<p><p>The summation-index technique was applied to flicker photometry to investigate the linearity law. Two test stimuli of different wavelengths were mixed, and the luminous efficiency of the mixture was measured under three different adapting conditions: no adaptation, 507-nm adaptation, and 650-nm adaptation. Most of the wavelength combinations and adapting conditions gave a summation index of 0.30, which is the linearity in the visual system that is responsible for the flicker perception, namely, the achromatic channel. An exception was the red and green combination under the no-adaptation condition, which gave a slightly smaller summation index than 0.30, indicating that these two stimuli do not add linearly. The subsummation was interpreted as cancellation of red and green responses in the red-versus-green opponent channel. The subsummation disappeared when the flicker frequency was increased from 5 to 12 Hz, confirming the interpretation.</p>","PeriodicalId":17413,"journal":{"name":"Journal of the Optical Society of America","volume":"73 8","pages":"1055-61"},"PeriodicalIF":0.0000,"publicationDate":"1983-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1364/josa.73.001055","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Optical Society of America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/josa.73.001055","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

The summation-index technique was applied to flicker photometry to investigate the linearity law. Two test stimuli of different wavelengths were mixed, and the luminous efficiency of the mixture was measured under three different adapting conditions: no adaptation, 507-nm adaptation, and 650-nm adaptation. Most of the wavelength combinations and adapting conditions gave a summation index of 0.30, which is the linearity in the visual system that is responsible for the flicker perception, namely, the achromatic channel. An exception was the red and green combination under the no-adaptation condition, which gave a slightly smaller summation index than 0.30, indicating that these two stimuli do not add linearly. The subsummation was interpreted as cancellation of red and green responses in the red-versus-green opponent channel. The subsummation disappeared when the flicker frequency was increased from 5 to 12 Hz, confirming the interpretation.

用综合指数法重新检验了闪烁测光的线性规律。
将求和指数技术应用于闪烁光度测量,研究了闪烁光度测量的线性规律。将两种不同波长的测试刺激混合,在不适应、507 nm适应和650 nm适应三种不同的适应条件下,测量混合后的发光效率。大多数波长组合和适应条件的总和指数为0.30,这是视觉系统中负责闪烁感知的线性度,即消色差通道。非适应条件下的红绿组合是一个例外,其总和指数略小于0.30,说明这两种刺激并不是线性相加的。合并被解释为在红色对绿色对手通道中红色和绿色反应的抵消。当闪烁频率从5 Hz增加到12 Hz时,合并消失,证实了解释。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
期刊介绍: OSA was published by The Optical Society from January 1917 to December 1983 before dividing into JOSA A: Optics and Image Science and JOSA B: Optical Physics in 1984.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信