[Pulsed Brain-Spoerel system a new closed-circle system (author's transl)].

Anesthesie, analgesie, reanimation Pub Date : 1981-01-01
A Neidhardt, M Audion, F Abourjaili
{"title":"[Pulsed Brain-Spoerel system a new closed-circle system (author's transl)].","authors":"A Neidhardt,&nbsp;M Audion,&nbsp;F Abourjaili","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A pump is used to reinsert the expiratory gas of a Bain Spoerel system into the circuit. It delivers a 14 l.min-1 flow. The expiratory gas is drawn across a CO2 absorber and fresh gas flow is reduced to the patient's VO2. The technic cumulates the advantages of the closed system to the Bain Spoerel system: practical design for head surgery, no valve, then less energetic loss by the patient in spontaneous ventilation, convenient gas flow, adapted to the small child, because of small dead space, economy of drugs, ecology: no more pollution ! humidification and warming of inspired gas. A hundred patients have been so anaesthetized in head surgery without any problem.</p>","PeriodicalId":7785,"journal":{"name":"Anesthesie, analgesie, reanimation","volume":"38 9-10","pages":"501-3"},"PeriodicalIF":0.0000,"publicationDate":"1981-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anesthesie, analgesie, reanimation","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A pump is used to reinsert the expiratory gas of a Bain Spoerel system into the circuit. It delivers a 14 l.min-1 flow. The expiratory gas is drawn across a CO2 absorber and fresh gas flow is reduced to the patient's VO2. The technic cumulates the advantages of the closed system to the Bain Spoerel system: practical design for head surgery, no valve, then less energetic loss by the patient in spontaneous ventilation, convenient gas flow, adapted to the small child, because of small dead space, economy of drugs, ecology: no more pollution ! humidification and warming of inspired gas. A hundred patients have been so anaesthetized in head surgery without any problem.

[脉冲脑- spoerel系统——一种新型闭环系统]。
一个泵被用来重新插入贝恩斯波尔系统的呼气气体到电路中。它提供了14 l.min-1流量。呼气气体被吸入二氧化碳吸收器,新鲜气体流被减少为患者的VO2。该技术将封闭系统的优点累积到Bain Spoerel系统:适用于头部手术的实用设计,无阀门,患者自发通气时能量损失少,气体流动方便,适合小孩,因死区小,药物经济,生态:不再污染!吸气气体的加湿和加热。有100个病人在头部手术中被如此麻醉而没有任何问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信