[Abortion at 10 to 12 weeks using a plastic syringe or electric aspirator].

E Borko, R Breznik, V Ivanisević, Z Kokos
{"title":"[Abortion at 10 to 12 weeks using a plastic syringe or electric aspirator].","authors":"E Borko,&nbsp;R Breznik,&nbsp;V Ivanisević,&nbsp;Z Kokos","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The study included 170 women subjected to menstrual regulation. The double-valve band syringe was used in 96 and the electric pump (the vacuum source usually used at the Department) in 74 cases. Nearly all the procedures were performed under general anesthesia, using 8 mm, 10 mm or 12 mm plastic rigid cannulae. Three abortions with the hand syringe also required dilatation and curettage, and all three women suffered blood loss exceeding 100 ml. There was one cervical laceration surgically repaired and a case of adnexitis reported among the hand syringe group. Immediate complications occurred in 7.3% of the cases using the hand syringe and in 4.1% of using the electric pump. The mean procedural time was 4.2 minutes and 4.0 minutes, respectively, with the hand syringe and the electric pump. Only three women reported complications or complaints at the follow-up visit, all of them from the electric pump group.</p>","PeriodicalId":76065,"journal":{"name":"Jugoslavenska ginekologija i opstetricija","volume":"23 1-2","pages":"17-20"},"PeriodicalIF":0.0000,"publicationDate":"1983-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jugoslavenska ginekologija i opstetricija","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The study included 170 women subjected to menstrual regulation. The double-valve band syringe was used in 96 and the electric pump (the vacuum source usually used at the Department) in 74 cases. Nearly all the procedures were performed under general anesthesia, using 8 mm, 10 mm or 12 mm plastic rigid cannulae. Three abortions with the hand syringe also required dilatation and curettage, and all three women suffered blood loss exceeding 100 ml. There was one cervical laceration surgically repaired and a case of adnexitis reported among the hand syringe group. Immediate complications occurred in 7.3% of the cases using the hand syringe and in 4.1% of using the electric pump. The mean procedural time was 4.2 minutes and 4.0 minutes, respectively, with the hand syringe and the electric pump. Only three women reported complications or complaints at the follow-up visit, all of them from the electric pump group.

[10至12周流产,使用塑料注射器或电动吸引器]。
这项研究包括170名接受月经调节的女性。96例采用双阀带式注射器,74例采用电泵(科室常用的真空源)。几乎所有的手术都是在全身麻醉下进行的,使用8毫米、10毫米或12毫米的塑料刚性套管。手注射器流产3例,均需扩张刮除,出血量均超过100 ml。手注射器组1例宫颈撕裂伤手术修复,1例附件炎。使用手动注射器和电动泵的立即并发症发生率分别为7.3%和4.1%。手动注射器和电动泵的平均手术时间分别为4.2分钟和4.0分钟。只有三名妇女在随访中报告了并发症或抱怨,她们都来自电动泵组。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信