C Duvivier, J Didelon, J P Arnould, J M Zahm, E Puchelle, C Kopp, B Obrecht
{"title":"A new viscoelastometer for studying the rheological properties of bronchial mucus in clinical practice.","authors":"C Duvivier, J Didelon, J P Arnould, J M Zahm, E Puchelle, C Kopp, B Obrecht","doi":"10.3233/bir-1984-23s121","DOIUrl":null,"url":null,"abstract":"<p><p>In clinical practice, a wide variety of drugs are given to modify the rheological properties of bronchial mucus but they are frequently not correctly chosen because there is not a simple apparatus available for the routine measurement of the mucus viscoelasticity. We designed a new viscoelastometer which is easy to operate and permit accurate measurement of the viscoelastic properties of mucus. The system has a Couette geometry and requires a sample of 1 ml. The outer cylinder is thermostated and rotates at a constant rate. The resulting torque is measured on the inner cylinder using a microdisplacement transducer. The inner cylinder is suspended by a special wire system which maintains a constant 0.75 mm gap between the two cylinders. The apparent viscosity is calculated up to 100 Pa.s. at a low shear rate (0.4 s-1) and the elasticity is analyzed by a stress relaxation method. The characteristics of the apparatus and the typical viscoelasticity behaviour of several sputum samples are reported.</p>","PeriodicalId":79205,"journal":{"name":"Biorheology. Supplement : the official journal of the International Society of Biorheology","volume":"1 ","pages":"119-22"},"PeriodicalIF":0.0000,"publicationDate":"1984-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3233/bir-1984-23s121","citationCount":"16","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biorheology. Supplement : the official journal of the International Society of Biorheology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3233/bir-1984-23s121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 16
Abstract
In clinical practice, a wide variety of drugs are given to modify the rheological properties of bronchial mucus but they are frequently not correctly chosen because there is not a simple apparatus available for the routine measurement of the mucus viscoelasticity. We designed a new viscoelastometer which is easy to operate and permit accurate measurement of the viscoelastic properties of mucus. The system has a Couette geometry and requires a sample of 1 ml. The outer cylinder is thermostated and rotates at a constant rate. The resulting torque is measured on the inner cylinder using a microdisplacement transducer. The inner cylinder is suspended by a special wire system which maintains a constant 0.75 mm gap between the two cylinders. The apparent viscosity is calculated up to 100 Pa.s. at a low shear rate (0.4 s-1) and the elasticity is analyzed by a stress relaxation method. The characteristics of the apparatus and the typical viscoelasticity behaviour of several sputum samples are reported.