{"title":"Electrical impedance measurement of urinary bladder fullness.","authors":"J C Abbey,&nbsp;L Close","doi":"10.1080/16070658.1983.11689335","DOIUrl":null,"url":null,"abstract":"<p><p>A tetrapolar 75-kHz, 0.2-mA constant-current electrical impedance measuring system was used to monitor urinary volume change over 12 four-hour sessions in 20 male and 20 female normal human subjects. Two spot voltage electrodes (E) and two spot current electrodes (I) were applied 5 cm above the symphysis pubis at 15 cm interelectrode distances, 7.5 cm bilaterally from the midline. Five measurements of impedance and skin temperature were made at 15-minute intervals over 4 hours. Specific gravity, impedance change, and volume were recorded with each voided specimen. Suprailiac and infrascapular skinfolds, and circumference at iliac crests were measured. The subjects drank 175 ml of fluids per hour during the testing session. Subjects remained in the supine position during measurements. They walked to the lavatory to void. Bladder fullness is defined as the urge to void. Results include: (1) a poor negative correlation between specific gravity of urine and impedance (r2 = 0.1240, p less than or equal to 0.01); (2) baseline impedance was dependent upon individual subject characteristics: in males skin area, skinfold thickness, and suprailiac circumference; in females skinfold thicknesses and time since last menstrual period; (3) impedance decreased with urinary bladder filling and increased upon voiding (p less than or equal to 10(-10)); (4) the cumulative sum test (CUSUM) predicted time to void in 78.9% of voids (p less than or equal to 0.05) and no void (when voiding did not occur) in 66.8% of no voids (p less than or equal to 0.05). Overall accuracy of the CUSUM test was 74.6% (p less than or equal to 0.05).</p>","PeriodicalId":76653,"journal":{"name":"The Journal of microwave power","volume":"18 3","pages":"305-9"},"PeriodicalIF":0.0000,"publicationDate":"1983-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/16070658.1983.11689335","citationCount":"15","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of microwave power","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/16070658.1983.11689335","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

Abstract

A tetrapolar 75-kHz, 0.2-mA constant-current electrical impedance measuring system was used to monitor urinary volume change over 12 four-hour sessions in 20 male and 20 female normal human subjects. Two spot voltage electrodes (E) and two spot current electrodes (I) were applied 5 cm above the symphysis pubis at 15 cm interelectrode distances, 7.5 cm bilaterally from the midline. Five measurements of impedance and skin temperature were made at 15-minute intervals over 4 hours. Specific gravity, impedance change, and volume were recorded with each voided specimen. Suprailiac and infrascapular skinfolds, and circumference at iliac crests were measured. The subjects drank 175 ml of fluids per hour during the testing session. Subjects remained in the supine position during measurements. They walked to the lavatory to void. Bladder fullness is defined as the urge to void. Results include: (1) a poor negative correlation between specific gravity of urine and impedance (r2 = 0.1240, p less than or equal to 0.01); (2) baseline impedance was dependent upon individual subject characteristics: in males skin area, skinfold thickness, and suprailiac circumference; in females skinfold thicknesses and time since last menstrual period; (3) impedance decreased with urinary bladder filling and increased upon voiding (p less than or equal to 10(-10)); (4) the cumulative sum test (CUSUM) predicted time to void in 78.9% of voids (p less than or equal to 0.05) and no void (when voiding did not occur) in 66.8% of no voids (p less than or equal to 0.05). Overall accuracy of the CUSUM test was 74.6% (p less than or equal to 0.05).

膀胱充盈度的电阻抗测量。
采用四极75 khz、0.2 ma恒流电阻抗测量系统监测20名男性和20名女性正常受试者12个4小时的尿量变化。两个点电压电极(E)和两个点电流电极(I)置于耻骨联合上方5cm处,电极间距为15cm,距中线7.5 cm。在4小时内,每隔15分钟测量5次阻抗和皮肤温度。记录每个空化标本的比重、阻抗变化和体积。测量髂上、肩胛下皮肤皱襞及髂嵴围度。在测试期间,受试者每小时喝175毫升的液体。测量期间受试者保持仰卧位。他们走到厕所去小便。膀胱充盈被定义为排空的冲动。结果表明:(1)尿比重与阻抗负相关较差(r2 = 0.1240, p小于等于0.01);(2)基线阻抗依赖于个体受试者特征:男性皮肤面积、皮褶厚度和滑上围;女性自最后一次月经以来的皮褶厚度和时间;(3)膀胱充盈时阻抗降低,排尿时阻抗升高(p≤10(-10));(4)累积总和试验(CUSUM)预测排空时间为78.9% (p小于等于0.05),未排空时间为66.8% (p小于等于0.05)。CUSUM试验的总体准确度为74.6% (p≤0.05)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信