A low-cost modular oxygen-consumption device for small animals.

P A Arundel, B R Holloway, P M Mellor
{"title":"A low-cost modular oxygen-consumption device for small animals.","authors":"P A Arundel,&nbsp;B R Holloway,&nbsp;P M Mellor","doi":"10.1152/jappl.1984.57.5.1591","DOIUrl":null,"url":null,"abstract":"<p><p>This paper describes a simple apparatus enabling the O2 consumption of small animals to be monitored. The system consists of a sensitive solid-state pressure transducer linked via a relay to a small peristaltic pump. While the animal breathes air in its closed chamber the CO2 expired is removed by an absorber; hence the pressure falls. The signal is sensed by the transducer triggering the pump to deliver a set volume of O2 to the chamber. The number of pump operations per unit time necessary to keep the system equilibrated is a measure of the O2 consumption rate. Each device is built as a module, up to four being mounted in one assembly controlled by a microcomputer. A balance control, priming switch, pump-volume setting, and electromagnetic counter are built into each front panel. Calibration is achieved be removing a known volume of air from the system with no animal present and counting the number of operations to return the chamber to equilibrium.</p>","PeriodicalId":15258,"journal":{"name":"Journal of applied physiology: respiratory, environmental and exercise physiology","volume":"57 5","pages":"1591-3"},"PeriodicalIF":0.0000,"publicationDate":"1984-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1152/jappl.1984.57.5.1591","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied physiology: respiratory, environmental and exercise physiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1152/jappl.1984.57.5.1591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper describes a simple apparatus enabling the O2 consumption of small animals to be monitored. The system consists of a sensitive solid-state pressure transducer linked via a relay to a small peristaltic pump. While the animal breathes air in its closed chamber the CO2 expired is removed by an absorber; hence the pressure falls. The signal is sensed by the transducer triggering the pump to deliver a set volume of O2 to the chamber. The number of pump operations per unit time necessary to keep the system equilibrated is a measure of the O2 consumption rate. Each device is built as a module, up to four being mounted in one assembly controlled by a microcomputer. A balance control, priming switch, pump-volume setting, and electromagnetic counter are built into each front panel. Calibration is achieved be removing a known volume of air from the system with no animal present and counting the number of operations to return the chamber to equilibrium.

一种低成本模块化小动物耗氧装置。
本文介绍了一种可以监测小动物耗氧量的简易装置。该系统由一个灵敏的固态压力传感器组成,通过继电器连接到一个小型蠕动泵。当动物在封闭的室内呼吸空气时,呼出的二氧化碳被吸收器除去;因此压力下降。换能器感应到信号,触发泵向腔室输送一定体积的氧气。单位时间内保持系统平衡所需的泵操作次数是氧气消耗率的度量。每个设备都是一个模块,最多四个被安装在一个由微型计算机控制的组件中。平衡控制,启动开关,泵量设置和电磁计数器内置于每个前面板。在没有动物存在的情况下,从系统中去除已知体积的空气,并计算使腔室恢复平衡的操作次数,从而实现校准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信