Measurement of pulmonary clearance of radioaerosol using a portable sodium iodide probe.

A L Jefferies, G Coates, C E Webber, H M O'Brodovich
{"title":"Measurement of pulmonary clearance of radioaerosol using a portable sodium iodide probe.","authors":"A L Jefferies,&nbsp;G Coates,&nbsp;C E Webber,&nbsp;H M O'Brodovich","doi":"10.1152/jappl.1984.57.6.1908","DOIUrl":null,"url":null,"abstract":"<p><p>To determine whether a portable sodium iodide (NaI) probe could provide a valid measure of the pulmonary half-life (T1/2) of aerosolized technetium-99m-diethylenetriaminepentaacetate (99mTc-DTPA, mol wt = 492) in small chests, we measured pulmonary clearance in rabbits using a gamma-scintillation camera and the portable probe. In 10 experiments the lungs of New Zealand White rabbits were insufflated with aerosolized 99mTc-DTPA (0.6 mum aerodynamic mass median diameter) and then simultaneously imaged with the gamma-camera and the probe positioned over the upper right lung. In an additional 12 experiments, alveolar-capillary membrane permeability was increased by either intratracheal instillation of 0.1 N hydrochloric acid (HCl) or intravenous injection of 100 mg/kg of oleic acid. All animals tolerated the procedure. There was a significant decrease in pulmonary T1/2 in both the HCl group (53.4 +/- 10.4 min, mean +/- SE) and the oleic acid group (14.7 +/- 2.3 min) when compared with control (127.5 +/- 18.1 min). When we compared the T 1/2 of the right lung determined by the gamma-camera with that measured by the probe, the correlation coefficient was 0.95. Potential nonpulmonary contributions to thoracic radioactivity were not significant. We conclude that a portable NaI probe is a valid means of determining T 1/2 of 99mTc-DTPA in small chests when compared with a gamma-camera and can detect increases in the permeability of the alveolar-capillary membrane to small solutes.</p>","PeriodicalId":15258,"journal":{"name":"Journal of applied physiology: respiratory, environmental and exercise physiology","volume":"57 6","pages":"1908-12"},"PeriodicalIF":0.0000,"publicationDate":"1984-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1152/jappl.1984.57.6.1908","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of applied physiology: respiratory, environmental and exercise physiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1152/jappl.1984.57.6.1908","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

To determine whether a portable sodium iodide (NaI) probe could provide a valid measure of the pulmonary half-life (T1/2) of aerosolized technetium-99m-diethylenetriaminepentaacetate (99mTc-DTPA, mol wt = 492) in small chests, we measured pulmonary clearance in rabbits using a gamma-scintillation camera and the portable probe. In 10 experiments the lungs of New Zealand White rabbits were insufflated with aerosolized 99mTc-DTPA (0.6 mum aerodynamic mass median diameter) and then simultaneously imaged with the gamma-camera and the probe positioned over the upper right lung. In an additional 12 experiments, alveolar-capillary membrane permeability was increased by either intratracheal instillation of 0.1 N hydrochloric acid (HCl) or intravenous injection of 100 mg/kg of oleic acid. All animals tolerated the procedure. There was a significant decrease in pulmonary T1/2 in both the HCl group (53.4 +/- 10.4 min, mean +/- SE) and the oleic acid group (14.7 +/- 2.3 min) when compared with control (127.5 +/- 18.1 min). When we compared the T 1/2 of the right lung determined by the gamma-camera with that measured by the probe, the correlation coefficient was 0.95. Potential nonpulmonary contributions to thoracic radioactivity were not significant. We conclude that a portable NaI probe is a valid means of determining T 1/2 of 99mTc-DTPA in small chests when compared with a gamma-camera and can detect increases in the permeability of the alveolar-capillary membrane to small solutes.

用便携式碘化钠探针测量放射性气溶胶的肺部清除率。
为了确定便携式碘化钠(NaI)探针是否能有效测量雾化的锝-99m-二乙烯三胺五乙酸酯(99mTc-DTPA, mol wt = 492)在小胸腔中的肺半衰期(T1/2),我们使用伽玛闪烁相机和便携式探针测量了家兔的肺清除率。在10个实验中,将雾化的99mTc-DTPA (0.6 μ m空气动力学质量中位直径)注入新西兰大白兔的肺中,然后同时用伽玛相机和位于右上肺上方的探针成像。在另外12个实验中,气管内注射0.1 N盐酸(HCl)或静脉注射100 mg/kg油酸均可增加肺泡毛细血管膜通透性。所有的动物都能忍受这个过程。与对照组(127.5 +/- 18.1 min)相比,HCl组(53.4 +/- 10.4 min,平均+/- SE)和油酸组(14.7 +/- 2.3 min)肺T1/2明显降低。当我们将伽玛相机测量的右肺t1 /2与探针测量的结果进行比较时,相关系数为0.95。潜在的非肺部对胸部放射性的影响不显著。我们得出的结论是,与伽马照相机相比,便携式NaI探针是测定小胸腔中99mTc-DTPA的t1 /2的有效手段,并且可以检测肺泡毛细血管膜对小溶质的通透性增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信