Continuous-flow techniques for tests in clinical chemistry.

D W Neill, J R Doggart
{"title":"Continuous-flow techniques for tests in clinical chemistry.","authors":"D W Neill, J R Doggart","doi":"10.1136/jcp.s2-3.1.39","DOIUrl":null,"url":null,"abstract":"The title of this paper is, for the hospital biochemist, synonymous with AutoAnalyzer techniques, and it is with the development and evolution of the AutoAnalyzer that it must inevitably deal. The next paper gives an account of the intensive developments which are taking place in the application of discrete analysis systems. This is perhaps the more difficult task, since, while there are many examples of this type there is effectively only one continuous-flow analytical technique. To the industrial analytical chemist coming into the field of clinical chemistry 18 years ago, it seemed that the methods employed lacked the absolute character which obtain in the industrial field. The reasons implicit in the study of biological material soon became obvious and the work load overwhelming, so that any naive concept of bringing the cold purity of absolute analytical accuracy to bear in this new field was gladly abandoned. It is important, however, to remember this feeling, because there is a tendency to approach automated techniques in a highly critical fashion, examining the performance of this or that system against the yardstick of a sanctified manual system of clinical chemistry which never had any reality. The principles of the single-channel AutoAnalyzer are now widely known, since subsequent changes in design have not fundamentally altered the approach so brilliantly described by Skeggs (1957). It was his recognition of the non-absolute character of clinical chemical methods, to which attention has been drawn above, which is fundamental to the success of the AutoAnalyzer. It was not important or even desirable to produce a machine capable of estimating urea concentration with absolute accuracy. If the machine could be guaranteed to treat every sample in exactly the same way so that standards were treated in the same way as tests, then the approach usual in manual methods would be operative. Indeed since machines have no free will and do not tire, it would be reasonable to expect greater precision.","PeriodicalId":78352,"journal":{"name":"Journal of clinical pathology. Supplement (College of Pathologists)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1969-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1136/jcp.s2-3.1.39","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical pathology. Supplement (College of Pathologists)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/jcp.s2-3.1.39","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The title of this paper is, for the hospital biochemist, synonymous with AutoAnalyzer techniques, and it is with the development and evolution of the AutoAnalyzer that it must inevitably deal. The next paper gives an account of the intensive developments which are taking place in the application of discrete analysis systems. This is perhaps the more difficult task, since, while there are many examples of this type there is effectively only one continuous-flow analytical technique. To the industrial analytical chemist coming into the field of clinical chemistry 18 years ago, it seemed that the methods employed lacked the absolute character which obtain in the industrial field. The reasons implicit in the study of biological material soon became obvious and the work load overwhelming, so that any naive concept of bringing the cold purity of absolute analytical accuracy to bear in this new field was gladly abandoned. It is important, however, to remember this feeling, because there is a tendency to approach automated techniques in a highly critical fashion, examining the performance of this or that system against the yardstick of a sanctified manual system of clinical chemistry which never had any reality. The principles of the single-channel AutoAnalyzer are now widely known, since subsequent changes in design have not fundamentally altered the approach so brilliantly described by Skeggs (1957). It was his recognition of the non-absolute character of clinical chemical methods, to which attention has been drawn above, which is fundamental to the success of the AutoAnalyzer. It was not important or even desirable to produce a machine capable of estimating urea concentration with absolute accuracy. If the machine could be guaranteed to treat every sample in exactly the same way so that standards were treated in the same way as tests, then the approach usual in manual methods would be operative. Indeed since machines have no free will and do not tire, it would be reasonable to expect greater precision.
临床化学试验用连续流技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信