{"title":"Pulse code modulation telemetry in ski injury research. I. Instrumentation.","authors":"M L Hull, C D Mote","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Measurement problems can be classified into instrumentation, data transmission and recording, and analysis. This paper focuses on the transmission of multichannel, high-volume, high-frequency, high-accuracy data. Boot-ski dynamometer and skier velocity anemometer data provide 13 channels of max. 8-mV signals requiring 8-microvolt resolution or 4.45-Newton dynamometer resolution. The data transmission system features durability, power consumption approx. 10 Watts, weight 4.54 kp, range greater than 3,500 m, frequency response 250 Hz, accuracy 1 per cent, temperature stability, dynamic range plus or minus 2 inches. The transducer signals are ampflified to plus or minus 10 V for the 100-kbps PCM system. Special AC amplifiers, driven by an amplitude-stabilized power oscillator, were designed for elimination of radio frequency interference (RFI), improved stability and high signal/noise. Sixteen words are sequentially sampled at 521/sec-13 data, 2 frame counters, and 1 sync. The ground station consists of the PCM decoder with real-time capability and an analog tape recorder. Data is subsequently buffered and formatted onto digital tape by mini-computer.</p>","PeriodicalId":75602,"journal":{"name":"Biotelemetry","volume":"1 4","pages":"182-92"},"PeriodicalIF":0.0000,"publicationDate":"1974-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Measurement problems can be classified into instrumentation, data transmission and recording, and analysis. This paper focuses on the transmission of multichannel, high-volume, high-frequency, high-accuracy data. Boot-ski dynamometer and skier velocity anemometer data provide 13 channels of max. 8-mV signals requiring 8-microvolt resolution or 4.45-Newton dynamometer resolution. The data transmission system features durability, power consumption approx. 10 Watts, weight 4.54 kp, range greater than 3,500 m, frequency response 250 Hz, accuracy 1 per cent, temperature stability, dynamic range plus or minus 2 inches. The transducer signals are ampflified to plus or minus 10 V for the 100-kbps PCM system. Special AC amplifiers, driven by an amplitude-stabilized power oscillator, were designed for elimination of radio frequency interference (RFI), improved stability and high signal/noise. Sixteen words are sequentially sampled at 521/sec-13 data, 2 frame counters, and 1 sync. The ground station consists of the PCM decoder with real-time capability and an analog tape recorder. Data is subsequently buffered and formatted onto digital tape by mini-computer.