Haemodialysis in dogs with a heparin coated hollow fibre dialyser.

L E Lins, P Olsson, M B Hjelte, R Larsson, O Larm
{"title":"Haemodialysis in dogs with a heparin coated hollow fibre dialyser.","authors":"L E Lins,&nbsp;P Olsson,&nbsp;M B Hjelte,&nbsp;R Larsson,&nbsp;O Larm","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Haemodialysis was performed in non-uraemic dogs with equipment coated with a stable heparin. During a three hour dialysis a constant blood flow of 205 ml/min was easily maintained. There was no increase in whole blood coagulation time and no heparin release from the surface. The platelet count was initially reduced by 15 per cent, but remained constant at this value throughout the dialysis. No increase in FPA concentration was detected. Heparin coating on inherently thrombogenic materials enables haemodialysis in the absence of systemic anticoagulation and without measurable activation of the haemostatic mechanism.</p>","PeriodicalId":77886,"journal":{"name":"Proceedings of the European Dialysis and Transplant Association - European Renal Association. European Dialysis and Transplant Association - European Renal Association. Congress","volume":"21 ","pages":"270-5"},"PeriodicalIF":0.0000,"publicationDate":"1985-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the European Dialysis and Transplant Association - European Renal Association. European Dialysis and Transplant Association - European Renal Association. Congress","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Haemodialysis was performed in non-uraemic dogs with equipment coated with a stable heparin. During a three hour dialysis a constant blood flow of 205 ml/min was easily maintained. There was no increase in whole blood coagulation time and no heparin release from the surface. The platelet count was initially reduced by 15 per cent, but remained constant at this value throughout the dialysis. No increase in FPA concentration was detected. Heparin coating on inherently thrombogenic materials enables haemodialysis in the absence of systemic anticoagulation and without measurable activation of the haemostatic mechanism.

肝素包覆中空纤维透析器在犬血液透析中的应用。
血液透析是在非尿毒症的狗与设备涂层稳定的肝素进行。在三小时的透析中,很容易维持205 ml/min的恒定血流量。全血凝固时间未增加,肝素未从表面释放。血小板计数最初减少了15%,但在整个透析过程中保持不变。未见FPA浓度升高。肝素涂层在固有的血栓形成材料使血液透析在缺乏全身抗凝和没有可测量的激活止血机制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信