A review of, and improvements to, the techniques of trace element analysis of raw water for home dialysis.

A P Cameron, P J Drury, P R Ineson, G A Harston
{"title":"A review of, and improvements to, the techniques of trace element analysis of raw water for home dialysis.","authors":"A P Cameron,&nbsp;P J Drury,&nbsp;P R Ineson,&nbsp;G A Harston","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The optimum operating conditions for the measurement of aluminium and iron concentrations in water by atomic absorption spectrometry have been determined experimentally. The characteristics of an ion-selective electrode for the measurement of fluoride have also been investigated. Contrary to other work, the addition of acid to samples did not improve their storage stability, although the acid-washing of polyethylene containers is recommended for the storage of water.</p>","PeriodicalId":77869,"journal":{"name":"Life support systems : the journal of the European Society for Artificial Organs","volume":"4 1","pages":"1-13"},"PeriodicalIF":0.0000,"publicationDate":"1986-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Life support systems : the journal of the European Society for Artificial Organs","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The optimum operating conditions for the measurement of aluminium and iron concentrations in water by atomic absorption spectrometry have been determined experimentally. The characteristics of an ion-selective electrode for the measurement of fluoride have also been investigated. Contrary to other work, the addition of acid to samples did not improve their storage stability, although the acid-washing of polyethylene containers is recommended for the storage of water.

家庭透析原水微量元素分析技术综述及改进。
实验确定了原子吸收光谱法测定水中铝、铁浓度的最佳操作条件。对离子选择电极测量氟的特性也进行了研究。与其他工作相反,向样品中添加酸并没有提高它们的储存稳定性,尽管推荐对聚乙烯容器进行酸洗以储存水。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信