{"title":"Space orientation of total hip prosthesis. A method for three-dimensional determination.","authors":"K Herrlin, G Selvik, H Pettersson","doi":"10.1177/028418518602700602","DOIUrl":null,"url":null,"abstract":"<p><p>A method for in vivo determination of orientation and relation in space of components of total hip prosthesis is described. The method allows for determination of the orientation of the prosthetic components in well defined anatomic planes of the body. Furthermore the range of free motion from neutral position to the point of contact between the edge of the acetabular opening and the neck of the femoral component can be determined in various directions. To assess the accuracy of the calculations a phantom prosthesis was studied in nine different positions and the measurements of the space oriented parameters according to the present method correlated to measurements of the same parameters according to Selvik's stereophotogrammetric method. Good correlation was found. The role of prosthetic malpositioning and component interaction evaluated with the present method in the development of prosthetic loosening and displacement is discussed.</p>","PeriodicalId":7142,"journal":{"name":"Acta radiologica: diagnosis","volume":"27 6","pages":"619-27"},"PeriodicalIF":0.0000,"publicationDate":"1986-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/028418518602700602","citationCount":"31","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica: diagnosis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/028418518602700602","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31
Abstract
A method for in vivo determination of orientation and relation in space of components of total hip prosthesis is described. The method allows for determination of the orientation of the prosthetic components in well defined anatomic planes of the body. Furthermore the range of free motion from neutral position to the point of contact between the edge of the acetabular opening and the neck of the femoral component can be determined in various directions. To assess the accuracy of the calculations a phantom prosthesis was studied in nine different positions and the measurements of the space oriented parameters according to the present method correlated to measurements of the same parameters according to Selvik's stereophotogrammetric method. Good correlation was found. The role of prosthetic malpositioning and component interaction evaluated with the present method in the development of prosthetic loosening and displacement is discussed.