Comparative Two-Year Outcomes of Three Different Three-Piece Intraocular Lenses in Flanged Intrascleral Fixation.

IF 2.4
Burhan Başkan, Yusuf Evcimen
{"title":"Comparative Two-Year Outcomes of Three Different Three-Piece Intraocular Lenses in Flanged Intrascleral Fixation.","authors":"Burhan Başkan, Yusuf Evcimen","doi":"10.3390/medicina62101985","DOIUrl":null,"url":null,"abstract":"<p><p><i>Background and Objectives</i>: To compare 2-year positional stability, endothelial preservation, and visual outcomes of three three-piece intraocular lenses (IOLs) implanted by the Yamane technique: Eyecryl (polypropylene haptics, 5° haptic angulation), Sensar OptiBlue AR40e (polymethyl methacrylate [PMMA] haptics, 5° haptic angulation), and AcrySof MA60AC (PMMA haptics, 10° haptic angulation). <i>Materials and Methods</i>: Records of 192 consecutive patients (one eye per patient; no bilateral implantation) receiving a study IOL were reviewed; 145 patients (75.5%) completed 24 months of follow-up (Eyecryl 48 eyes, Sensar 48 eyes, MA60AC 49 eyes). Endothelial cell density (ECD) loss and anterior segment OCT measures of decentration, tilt, and anatomical anterior chamber depth (ACD) were modelled with mixed-effects models weighted by stabilised inverse probability of treatment weights, using cluster-robust standard errors. <i>Results</i>: Visual acuity gain was equivalent within the prespecified ±0.15 logMAR margin (two one-sided tests, <i>p</i> = 0.009). Operative time differed (Eyecryl 12.9 ± 3.4 versus MA60AC 24.1 ± 7.6 min; <i>p</i> < 0.001), as did the proportion of eyes requiring repeat cautery of at least one haptic (Eyecryl 4.2%, Sensar 22.9%, MA60AC 42.9%; <i>p</i> < 0.001). MA60AC showed greater decentration (0.75 ± 0.21 versus 0.56 ± 0.20 mm) and shallower ACD (3.42 ± 0.38 versus 3.61 ± 0.35 mm); tilt did not differ (omnibus <i>p</i> = 0.312). Unadjusted 24-month ECD loss, expressed as a percentage of baseline ECD, was 4.92 ± 1.52% (Eyecryl), 6.18 ± 1.87% (Sensar), and 7.45 ± 2.01% (MA60AC) (all pairwise <i>p</i> < 0.0167). After operative duration, ACD, and decentration were entered, the MA60AC-versus-Eyecryl difference in ECD loss fell by 81.4%, from 2.1 to a non-significant 0.4 percentage points; this attenuation is descriptive, not causal mediation. <i>Conclusions</i>: All three platforms gave equivalent 2-year visual outcomes. Eyecryl showed better positional stability and lower unadjusted endothelial loss than MA60AC, with shorter surgery and a less anterior optic. Because haptic material and angulation vary together here, comparisons concern whole platforms, not individual attributes.</p>","PeriodicalId":520709,"journal":{"name":"Medicina (Kaunas, Lithuania)","volume":"62 10","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicina (Kaunas, Lithuania)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/medicina62101985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background and Objectives: To compare 2-year positional stability, endothelial preservation, and visual outcomes of three three-piece intraocular lenses (IOLs) implanted by the Yamane technique: Eyecryl (polypropylene haptics, 5° haptic angulation), Sensar OptiBlue AR40e (polymethyl methacrylate [PMMA] haptics, 5° haptic angulation), and AcrySof MA60AC (PMMA haptics, 10° haptic angulation). Materials and Methods: Records of 192 consecutive patients (one eye per patient; no bilateral implantation) receiving a study IOL were reviewed; 145 patients (75.5%) completed 24 months of follow-up (Eyecryl 48 eyes, Sensar 48 eyes, MA60AC 49 eyes). Endothelial cell density (ECD) loss and anterior segment OCT measures of decentration, tilt, and anatomical anterior chamber depth (ACD) were modelled with mixed-effects models weighted by stabilised inverse probability of treatment weights, using cluster-robust standard errors. Results: Visual acuity gain was equivalent within the prespecified ±0.15 logMAR margin (two one-sided tests, p = 0.009). Operative time differed (Eyecryl 12.9 ± 3.4 versus MA60AC 24.1 ± 7.6 min; p < 0.001), as did the proportion of eyes requiring repeat cautery of at least one haptic (Eyecryl 4.2%, Sensar 22.9%, MA60AC 42.9%; p < 0.001). MA60AC showed greater decentration (0.75 ± 0.21 versus 0.56 ± 0.20 mm) and shallower ACD (3.42 ± 0.38 versus 3.61 ± 0.35 mm); tilt did not differ (omnibus p = 0.312). Unadjusted 24-month ECD loss, expressed as a percentage of baseline ECD, was 4.92 ± 1.52% (Eyecryl), 6.18 ± 1.87% (Sensar), and 7.45 ± 2.01% (MA60AC) (all pairwise p < 0.0167). After operative duration, ACD, and decentration were entered, the MA60AC-versus-Eyecryl difference in ECD loss fell by 81.4%, from 2.1 to a non-significant 0.4 percentage points; this attenuation is descriptive, not causal mediation. Conclusions: All three platforms gave equivalent 2-year visual outcomes. Eyecryl showed better positional stability and lower unadjusted endothelial loss than MA60AC, with shorter surgery and a less anterior optic. Because haptic material and angulation vary together here, comparisons concern whole platforms, not individual attributes.

三种不同的三片式人工晶状体在法兰巩膜内固定的两年疗效比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书