Continuously tunable attenuation stage for weak-light radiance calibration using an integrating sphere and a dual-aperture tube.

Applied optics Pub Date : 2026-10-10 Epub Date: 2026-09-14 DOI:10.1364/AO.612091
Wentao Wang, Jianjun Li, Qing Kang, Xiaobing Zheng
{"title":"Continuously tunable attenuation stage for weak-light radiance calibration using an integrating sphere and a dual-aperture tube.","authors":"Wentao Wang, Jianjun Li, Qing Kang, Xiaobing Zheng","doi":"10.1364/AO.612091","DOIUrl":null,"url":null,"abstract":"<p><p>We present a continuously tunable weak-light attenuation stage combining an integrating sphere with a coaxial dual-aperture tube. An exact view-factor model provides the geometry-based reference, and a monitor-normalized calibration produced a 22×22 attenuation matrix spanning 0-40.36 dB. A separable correction reduced the in-grid residual RMS to 0.017 dB. Independent target-setting validation over 5.0-39.1 dB yielded an RMS residual of 0.091 dB. Measured spatial and angular departures of the input field were propagated into the uncertainty budget, giving an expanded uncertainty of 0.021-0.036 dB (<i>k</i>=2). Spectral-shape RMS deviations remained within 0.477% up to 15 dB.</p>","PeriodicalId":101299,"journal":{"name":"Applied optics","volume":"65 29","pages":"10076-10087"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/AO.612091","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/14 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

We present a continuously tunable weak-light attenuation stage combining an integrating sphere with a coaxial dual-aperture tube. An exact view-factor model provides the geometry-based reference, and a monitor-normalized calibration produced a 22×22 attenuation matrix spanning 0-40.36 dB. A separable correction reduced the in-grid residual RMS to 0.017 dB. Independent target-setting validation over 5.0-39.1 dB yielded an RMS residual of 0.091 dB. Measured spatial and angular departures of the input field were propagated into the uncertainty budget, giving an expanded uncertainty of 0.021-0.036 dB (k=2). Spectral-shape RMS deviations remained within 0.477% up to 15 dB.

使用积分球和双孔径管进行弱光辐射校准的连续可调衰减阶段。
我们提出了一种将积分球与同轴双孔径管相结合的连续可调谐弱光衰减台。精确的视因子模型提供了基于几何的参考,监视器归一化校准产生了0-40.36 dB的22×22衰减矩阵。可分离校正将网格内残差RMS降低到0.017 dB。在5.0-39.1 dB范围内的独立目标设置验证的RMS残差为0.091 dB。测量的输入场的空间和角度偏离被传播到不确定度预算中,得到0.021-0.036 dB (k=2)的扩展不确定度。在15 dB范围内,谱形均方根偏差保持在0.477%以内。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书