{"title":"Phase-edge imaging using q-plate shifts for faster and simpler microscopy.","authors":"Jigme Zangpo, Hirokazu Kobayashi, Ryo Yasuhara","doi":"10.1364/AO.608559","DOIUrl":null,"url":null,"abstract":"<p><p>We present a simplified method for isolating the edges of a phase object from the edges of an amplitude object using a 4<i>f</i> system with an off-axis q-plate. Instead of the four off-axis shifts of the q-plate required in previous work, we need only two shifts (along ±<i>x</i>) combined with linear polarizers at 45° and 135°. The number of required mechanical q-plate displacement directions is reduced from four to two. We derive the theoretical basis, showing that the resulting intensity corresponds to the phase gradient squared, with amplitude-object contributions eliminated. Experiments on two phase-amplitude object samples demonstrate amplitude-edge reduction of up to 97.6% and correlation coefficients of up to 0.80 (sample 1) and 0.75 (sample 2). In overlapping regions, the phase edge is partially recovered; full recovery would require additional processing such as inverse filtering. This research is useful for biological imaging applications where fast and simple phase-edge isolation is desired.</p>","PeriodicalId":101299,"journal":{"name":"Applied optics","volume":"65 29","pages":"10178-10184"},"PeriodicalIF":0.0000,"publicationDate":"2026-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/AO.608559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
We present a simplified method for isolating the edges of a phase object from the edges of an amplitude object using a 4f system with an off-axis q-plate. Instead of the four off-axis shifts of the q-plate required in previous work, we need only two shifts (along ±x) combined with linear polarizers at 45° and 135°. The number of required mechanical q-plate displacement directions is reduced from four to two. We derive the theoretical basis, showing that the resulting intensity corresponds to the phase gradient squared, with amplitude-object contributions eliminated. Experiments on two phase-amplitude object samples demonstrate amplitude-edge reduction of up to 97.6% and correlation coefficients of up to 0.80 (sample 1) and 0.75 (sample 2). In overlapping regions, the phase edge is partially recovered; full recovery would require additional processing such as inverse filtering. This research is useful for biological imaging applications where fast and simple phase-edge isolation is desired.