{"title":"Validation of an AI-Driven Sputum Analysis Platform for Accurate and Reliable Tuberculosis Detection in South-Western Uganda.","authors":"Habert Tumwesigye, Daniel Atwine, Raymond Atwine, Abraham Birungi, Caroline Birungi, Esther Munguciada, Phionah Nabimanya, Joseph Akandwanaho, Benard Ochama, Yekosani Mitala","doi":"10.2147/MDER.S639007","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ziehl-Neelsen (ZN) sputum smear microscopy remains an accessible method for detecting acid-fast bacilli (AFB), but its interpretation is dependent on specimen quality and trained microscopy personnel. Artificial intelligence (AI) may provide a microscopy reading aid that supports consistent identification of AFB-positive and AFB-negative smear images.</p><p><strong>Objective: </strong>To evaluate transfer-learning deep learning models for classification of AFB-positive and AFB-negative digitized ZN-stained sputum smear images generated in a Ugandan regional referral laboratory.</p><p><strong>Methods: </strong>A retrospective laboratory-based cross-sectional study used 512 archived digitized ZN-stained sputum smear images from Mbarara Regional Referral Hospital. The dataset contained 256 AFB-positive and 256 AFB-negative images and was partitioned by stratified sampling into training (n=358), validation (n=77), and an internal hold-out test set (n=77). ResNet-50 V2, DenseNet-121, and Swin Transformer-Tiny models were trained using ImageNet-pretrained weights in PyTorch. Performance was assessed using sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), F1-score, and ROC-AUC.</p><p><strong>Results: </strong>On the internal test set, Swin Transformer-Tiny achieved 97.40% accuracy, 97.37% sensitivity, 97.44% specificity, 97.37% PPV, 97.44% NPV, 97.37% F1-score, and ROC-AUC 0.9939. DenseNet-121 achieved 88.31% accuracy, 84.21% sensitivity, 92.31% specificity, and ROC-AUC 0.9730. ResNet-50 V2 achieved 85.71% accuracy, 81.58% sensitivity, 89.74% specificity, and ROC-AUC 0.9555. Wilson 95% confidence intervals were calculated for the threshold-based metrics.</p><p><strong>Conclusion: </strong>The models demonstrated promising internal performance for classification of microscopy-defined AFB status. Swin Transformer-Tiny had the highest observed performance, but the small, balanced, single-centre internal test set and use of routine microscopy labels rather than an independent microbiological reference standard limit clinical interpretation. The platform should therefore be considered an AI-assisted microscopy reading aid rather than an autonomous tuberculosis diagnostic system. Prospective, multicentre evaluation using patient/specimen-level separation, independent microbiological reference standards, and multiple blinded readers is required before clinical deployment.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":"19 ","pages":"639007"},"PeriodicalIF":1.5000,"publicationDate":"2026-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13679598/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S639007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Ziehl-Neelsen (ZN) sputum smear microscopy remains an accessible method for detecting acid-fast bacilli (AFB), but its interpretation is dependent on specimen quality and trained microscopy personnel. Artificial intelligence (AI) may provide a microscopy reading aid that supports consistent identification of AFB-positive and AFB-negative smear images.
Objective: To evaluate transfer-learning deep learning models for classification of AFB-positive and AFB-negative digitized ZN-stained sputum smear images generated in a Ugandan regional referral laboratory.
Methods: A retrospective laboratory-based cross-sectional study used 512 archived digitized ZN-stained sputum smear images from Mbarara Regional Referral Hospital. The dataset contained 256 AFB-positive and 256 AFB-negative images and was partitioned by stratified sampling into training (n=358), validation (n=77), and an internal hold-out test set (n=77). ResNet-50 V2, DenseNet-121, and Swin Transformer-Tiny models were trained using ImageNet-pretrained weights in PyTorch. Performance was assessed using sensitivity, specificity, accuracy, positive predictive value (PPV), negative predictive value (NPV), F1-score, and ROC-AUC.
Results: On the internal test set, Swin Transformer-Tiny achieved 97.40% accuracy, 97.37% sensitivity, 97.44% specificity, 97.37% PPV, 97.44% NPV, 97.37% F1-score, and ROC-AUC 0.9939. DenseNet-121 achieved 88.31% accuracy, 84.21% sensitivity, 92.31% specificity, and ROC-AUC 0.9730. ResNet-50 V2 achieved 85.71% accuracy, 81.58% sensitivity, 89.74% specificity, and ROC-AUC 0.9555. Wilson 95% confidence intervals were calculated for the threshold-based metrics.
Conclusion: The models demonstrated promising internal performance for classification of microscopy-defined AFB status. Swin Transformer-Tiny had the highest observed performance, but the small, balanced, single-centre internal test set and use of routine microscopy labels rather than an independent microbiological reference standard limit clinical interpretation. The platform should therefore be considered an AI-assisted microscopy reading aid rather than an autonomous tuberculosis diagnostic system. Prospective, multicentre evaluation using patient/specimen-level separation, independent microbiological reference standards, and multiple blinded readers is required before clinical deployment.