Beyond Removability: Can Multi-Hole Covered Metal Stents Overcome the Remaining Challenges in Malignant Hilar Biliary Obstruction?

IF 3.6 2区 医学 Q1 GASTROENTEROLOGY & HEPATOLOGY
Hirofumi Kogure
{"title":"Beyond Removability: Can Multi-Hole Covered Metal Stents Overcome the Remaining Challenges in Malignant Hilar Biliary Obstruction?","authors":"Hirofumi Kogure","doi":"10.1111/den.70316","DOIUrl":null,"url":null,"abstract":"<p>Malignant hilar biliary obstruction (MHBO) remains one of the most technically demanding conditions in therapeutic pancreatobiliary endoscopy. Although bilateral drainage using uncovered self-expandable metal stents (UMSs) has conventionally been favored because of their prolonged patency and preservation of side-branch drainage, the non-removability of UMSs represents an increasingly important limitation. Improvements in systemic therapy have prolonged survival in patients with biliary tract and other malignancies, and recurrent biliary obstruction (RBO) after UMS placement is therefore encountered more frequently. Once the UMS becomes embedded in the bile duct wall due to tumor ingrowth or tissue hyperplasia, removal is generally impossible, and reintervention must be performed through or alongside the existing stent. This can restrict selective access to an undrained or newly obstructed segment, increase the complexity of repeated procedures, and leave a permanent metallic framework that may hinder subsequent modification of the drainage strategy or complicate conversion surgery. In this sense, removability is not simply a technical convenience: it preserves the option to reset the biliary anatomy at the time of reintervention.</p><p>Inoue et al. recently compared suprapapillary stent-by-stent deployment of 6-mm slim fully covered metal stents (FCMSs) with conventional UMS deployment for unresectable MHBO in a multicenter retrospective study [<span>1</span>]. After propensity score matching, 52 patients were included in each group. Technical and clinical success rates were comparable, whereas the FCMS group had a significantly lower incidence of RBO than the UMS group (32.0% vs. 60.8%) and a significantly longer time to RBO. Importantly, FCMSs could be removed in all patients undergoing reintervention. The reintervention time was shorter, and both the total number of reinterventions and the proportion of patients requiring multiple reinterventions were lower with FCMSs. These findings are important because they link removability not only to device retrieval but also to the cumulative burden of longitudinal biliary management.</p><p>The study therefore raises a broader question: should MHBO drainage primarily pursue “permanent drainage,” with the ideal goal of zero reintervention, or “removable drainage,” which accepts that reintervention may occur but seeks to make it predictable and technically straightforward? These aims should not be viewed as mutually exclusive or as a competition between devices. Rather, they represent different priorities along a patient's anticipated clinical course. Durable drainage with the lowest possible probability of another procedure may be the dominant objective in a patient with limited life expectancy or high procedural risk. By contrast, removability may be especially valuable in patients expected to receive prolonged systemic therapy, those likely to require repeated interventions, or those in whom conversion surgery remains a realistic possibility. The goal should therefore shift from identifying a universally superior stent to selecting a drainage strategy that retains sufficient patency while preserving the future options that are most relevant for the individual patient.</p><p>This perspective also clarifies the differences between plastic stents (PSs) and removable metal stents. Intraductal PSs can be electively exchanged or removed, with reliable removability demonstrated in patients with MHBO [<span>2</span>]. Their small caliber and relatively low radial force may reduce the consequences of branch coverage and make sequential reconstruction comparatively simple; however, they are more susceptible to clogging and generally require more frequent planned or on-demand exchange. In contrast, removable FCMSs provide a larger luminal diameter and have demonstrated longer stent patency than PSs in patients with MHBO [<span>3</span>]. The trade-off is that FCMSs exert greater radial force and their covering can obstruct side branches; migration, overgrowth at the stent ends, and tissue reaction can also complicate later removal. Thus, “removable” is not a binary property shared equally by PSs and FCMSs: PSs favor ease and repeatability of exchange, whereas FCMSs seek to combine removability with metal-stent caliber and durability.</p><p>What, then, determines good removability? First, the covering must remain mechanically intact and sufficiently impermeable to prevent tumor or hyperplastic tissue from fixing the stent to the duct wall. Covering material and architecture are therefore central, although comparative evidence specific to MHBO remains limited. Second, the stent should achieve enough radial force and anchoring to resist migration without creating excessive tissue reaction at uncovered ends or anchoring elements. Stent diameter may influence this balance: a slim FCMS can facilitate multistent deployment in the hilum, but diameter alone cannot guarantee removability. Third, proximal and distal positioning matters because an exposed edge at a bifurcation or within reactive tissue may become difficult to retrieve even when the body of the stent is fully covered. Finally, indwelling time is likely relevant. Data from non-malignant biliary strictures suggest that prolonged dwell time can increase FCMS removal failure through hyperplastic overgrowth [<span>4</span>], although the magnitude of this effect in malignant hilar disease is unknown. These considerations argue for evaluating removability as a time-dependent endpoint—successful atraumatic extraction after the clinically relevant dwell period—rather than as an intrinsic label attached to a stent at the time of deployment.</p><p>Suprapapillary placement may further improve the performance of slim FCMSs. Avoiding direct exposure of the stent lumen to duodenal contents could reduce duodenobiliary reflux and sludge formation, while the suprapapillary position may decrease distal migration into the duodenum. Nevertheless, the Inoue study also illustrates that removability does not eliminate the inherent disadvantages of covering the hilar biliary tree. Two patients in the FCMS group developed posterior-segment bilomas within 2 months, necessitating stent removal. In both cases, the proximal end of the right-sided FCMS was positioned at the bifurcation of the anterior and posterior sectoral ducts. Although a definite obstruction was not demonstrated, coverage of the posterior sectoral branch or disturbance of localized bile flow was strongly suspected. Thus, the proximal end of a covered stent may be as important as the stricture itself.</p><p>Branch occlusion can manifest not only as overt cholangitis but also as segmental cholangitis, liver abscess, or biloma. These events may be difficult to predict because apparently adequate contrast drainage at the end of the procedure does not necessarily guarantee sustained drainage after full stent expansion. Placing the proximal stent end precisely at a major bifurcation may be particularly hazardous. When both the anterior and posterior sectoral ducts remain patent, either complete bridging of the bifurcation or separate drainage using three stents may be preferable to leaving the covered stent edge at the bifurcation. Preprocedural assessment of the target liver volume and detailed interpretation of three-dimensional biliary anatomy are therefore essential. Preservation of segmental drainage is especially important when prolonged survival is anticipated because a small branch-related problem that might be clinically tolerable over weeks can become consequential over months of systemic therapy.</p><p>The branch-related adverse events observed with conventional slim FCMSs in the Inoue study provide a hypothesis for further stent design, rather than evidence for multi-hole fully covered self-expandable metal stents (MHSEMSs) themselves. Inoue et al. did not evaluate MHSEMSs. Conceptually, however, MHSEMSs incorporate multiple small holes into the covering membrane, with the aim of allowing bile to flow from adjacent branches while retaining many advantages of a covered stent. The holes may also permit limited tissue anchoring and thereby reduce migration. Successful suprapapillary stent-in-stent and side-by-side deployment of MHSEMSs for MHBO has been described, demonstrating technical feasibility while maintaining potential removability [<span>5, 6</span>]. A recent porcine hilar-obstruction model also suggested preservation of side-branch drainage and successful removability after MHSEMS placement [<span>7</span>]. These observations make the multi-hole concept attractive, but its clinical value in MHBO remains to be validated prospectively.</p><p>Clinical data from malignant distal biliary obstruction provide further proof of concept, while also illustrating the design trade-offs. In a multicenter retrospective study of 111 patients, the migration rate after MHSEMS placement was only 1.9%, and successful removal was achieved in 88.9% of attempted cases [<span>8</span>]. These findings suggest that a multi-hole design might address two important FCMS-related problems: side-branch obstruction and migration. In the hilar setting, communication through the holes might preserve drainage of a sectoral duct even when the stent edge or covered membrane overlaps a bifurcation. However, the same holes that permit branch drainage and tissue anchoring may allow tumor or hyperplastic tissue to grow into the stent. Indeed, ingrowth has been reported after MHSEMS placement for distal malignant biliary obstruction [<span>8</span>], and another comparative study in pancreatic cancer found a shorter time to RBO with MHSEMSs than with conventional FCMSs [<span>9</span>]. Reduced migration therefore does not necessarily translate into superior overall patency or easier late removal.</p><p>The ideal strategy for MHBO should therefore balance four longitudinal objectives: durable drainage, preservation of segmental bile flow, technical feasibility of multisegmental deployment, and the ability to revise or remove the stent when the clinical course changes. Conventional UMSs prioritize patency and branch preservation but sacrifice removability; PSs maximize exchangeability but usually at the cost of smaller caliber and more frequent reintervention; conventional FCMSs combine larger caliber with removability but may occlude branches or migrate; and MHSEMSs represent a rational attempt to reconcile these competing properties, although their benefits and trade-offs still require clinical validation. Future trials should compare these strategies using not only time to RBO but also successful removal at prespecified dwell periods, segment-specific adverse events, success of selective reintervention, cumulative number and duration of procedures, unplanned hospitalization, compatibility with subsequent surgery, and patient-reported burden. The next advance in MHBO drainage may depend less on whether a stent is simply covered or uncovered—or even removable or non-removable—than on how well the initial drainage plan anticipates the patient's likely oncological trajectory and preserves options for what comes next.</p><p><b>Hirofumi Kogure:</b> conceptualization; literature review; writing – original draft; writing – review and editing. The author approved the final version of the manuscript.</p><p>The author has nothing to report.</p><p>The author declares no conflicts of interest.</p><p>This article is linked with T. Inoue et al. To view this article visit https://doi.org/10.1111/den.70031.</p><p>Data sharing not applicable to this article as no datasets were generated or analysed during the current study.</p>","PeriodicalId":159,"journal":{"name":"Digestive Endoscopy","volume":"38 10","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2026-10-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/den.70316","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Endoscopy","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/den.70316","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Malignant hilar biliary obstruction (MHBO) remains one of the most technically demanding conditions in therapeutic pancreatobiliary endoscopy. Although bilateral drainage using uncovered self-expandable metal stents (UMSs) has conventionally been favored because of their prolonged patency and preservation of side-branch drainage, the non-removability of UMSs represents an increasingly important limitation. Improvements in systemic therapy have prolonged survival in patients with biliary tract and other malignancies, and recurrent biliary obstruction (RBO) after UMS placement is therefore encountered more frequently. Once the UMS becomes embedded in the bile duct wall due to tumor ingrowth or tissue hyperplasia, removal is generally impossible, and reintervention must be performed through or alongside the existing stent. This can restrict selective access to an undrained or newly obstructed segment, increase the complexity of repeated procedures, and leave a permanent metallic framework that may hinder subsequent modification of the drainage strategy or complicate conversion surgery. In this sense, removability is not simply a technical convenience: it preserves the option to reset the biliary anatomy at the time of reintervention.

Inoue et al. recently compared suprapapillary stent-by-stent deployment of 6-mm slim fully covered metal stents (FCMSs) with conventional UMS deployment for unresectable MHBO in a multicenter retrospective study [1]. After propensity score matching, 52 patients were included in each group. Technical and clinical success rates were comparable, whereas the FCMS group had a significantly lower incidence of RBO than the UMS group (32.0% vs. 60.8%) and a significantly longer time to RBO. Importantly, FCMSs could be removed in all patients undergoing reintervention. The reintervention time was shorter, and both the total number of reinterventions and the proportion of patients requiring multiple reinterventions were lower with FCMSs. These findings are important because they link removability not only to device retrieval but also to the cumulative burden of longitudinal biliary management.

The study therefore raises a broader question: should MHBO drainage primarily pursue “permanent drainage,” with the ideal goal of zero reintervention, or “removable drainage,” which accepts that reintervention may occur but seeks to make it predictable and technically straightforward? These aims should not be viewed as mutually exclusive or as a competition between devices. Rather, they represent different priorities along a patient's anticipated clinical course. Durable drainage with the lowest possible probability of another procedure may be the dominant objective in a patient with limited life expectancy or high procedural risk. By contrast, removability may be especially valuable in patients expected to receive prolonged systemic therapy, those likely to require repeated interventions, or those in whom conversion surgery remains a realistic possibility. The goal should therefore shift from identifying a universally superior stent to selecting a drainage strategy that retains sufficient patency while preserving the future options that are most relevant for the individual patient.

This perspective also clarifies the differences between plastic stents (PSs) and removable metal stents. Intraductal PSs can be electively exchanged or removed, with reliable removability demonstrated in patients with MHBO [2]. Their small caliber and relatively low radial force may reduce the consequences of branch coverage and make sequential reconstruction comparatively simple; however, they are more susceptible to clogging and generally require more frequent planned or on-demand exchange. In contrast, removable FCMSs provide a larger luminal diameter and have demonstrated longer stent patency than PSs in patients with MHBO [3]. The trade-off is that FCMSs exert greater radial force and their covering can obstruct side branches; migration, overgrowth at the stent ends, and tissue reaction can also complicate later removal. Thus, “removable” is not a binary property shared equally by PSs and FCMSs: PSs favor ease and repeatability of exchange, whereas FCMSs seek to combine removability with metal-stent caliber and durability.

What, then, determines good removability? First, the covering must remain mechanically intact and sufficiently impermeable to prevent tumor or hyperplastic tissue from fixing the stent to the duct wall. Covering material and architecture are therefore central, although comparative evidence specific to MHBO remains limited. Second, the stent should achieve enough radial force and anchoring to resist migration without creating excessive tissue reaction at uncovered ends or anchoring elements. Stent diameter may influence this balance: a slim FCMS can facilitate multistent deployment in the hilum, but diameter alone cannot guarantee removability. Third, proximal and distal positioning matters because an exposed edge at a bifurcation or within reactive tissue may become difficult to retrieve even when the body of the stent is fully covered. Finally, indwelling time is likely relevant. Data from non-malignant biliary strictures suggest that prolonged dwell time can increase FCMS removal failure through hyperplastic overgrowth [4], although the magnitude of this effect in malignant hilar disease is unknown. These considerations argue for evaluating removability as a time-dependent endpoint—successful atraumatic extraction after the clinically relevant dwell period—rather than as an intrinsic label attached to a stent at the time of deployment.

Suprapapillary placement may further improve the performance of slim FCMSs. Avoiding direct exposure of the stent lumen to duodenal contents could reduce duodenobiliary reflux and sludge formation, while the suprapapillary position may decrease distal migration into the duodenum. Nevertheless, the Inoue study also illustrates that removability does not eliminate the inherent disadvantages of covering the hilar biliary tree. Two patients in the FCMS group developed posterior-segment bilomas within 2 months, necessitating stent removal. In both cases, the proximal end of the right-sided FCMS was positioned at the bifurcation of the anterior and posterior sectoral ducts. Although a definite obstruction was not demonstrated, coverage of the posterior sectoral branch or disturbance of localized bile flow was strongly suspected. Thus, the proximal end of a covered stent may be as important as the stricture itself.

Branch occlusion can manifest not only as overt cholangitis but also as segmental cholangitis, liver abscess, or biloma. These events may be difficult to predict because apparently adequate contrast drainage at the end of the procedure does not necessarily guarantee sustained drainage after full stent expansion. Placing the proximal stent end precisely at a major bifurcation may be particularly hazardous. When both the anterior and posterior sectoral ducts remain patent, either complete bridging of the bifurcation or separate drainage using three stents may be preferable to leaving the covered stent edge at the bifurcation. Preprocedural assessment of the target liver volume and detailed interpretation of three-dimensional biliary anatomy are therefore essential. Preservation of segmental drainage is especially important when prolonged survival is anticipated because a small branch-related problem that might be clinically tolerable over weeks can become consequential over months of systemic therapy.

The branch-related adverse events observed with conventional slim FCMSs in the Inoue study provide a hypothesis for further stent design, rather than evidence for multi-hole fully covered self-expandable metal stents (MHSEMSs) themselves. Inoue et al. did not evaluate MHSEMSs. Conceptually, however, MHSEMSs incorporate multiple small holes into the covering membrane, with the aim of allowing bile to flow from adjacent branches while retaining many advantages of a covered stent. The holes may also permit limited tissue anchoring and thereby reduce migration. Successful suprapapillary stent-in-stent and side-by-side deployment of MHSEMSs for MHBO has been described, demonstrating technical feasibility while maintaining potential removability [5, 6]. A recent porcine hilar-obstruction model also suggested preservation of side-branch drainage and successful removability after MHSEMS placement [7]. These observations make the multi-hole concept attractive, but its clinical value in MHBO remains to be validated prospectively.

Clinical data from malignant distal biliary obstruction provide further proof of concept, while also illustrating the design trade-offs. In a multicenter retrospective study of 111 patients, the migration rate after MHSEMS placement was only 1.9%, and successful removal was achieved in 88.9% of attempted cases [8]. These findings suggest that a multi-hole design might address two important FCMS-related problems: side-branch obstruction and migration. In the hilar setting, communication through the holes might preserve drainage of a sectoral duct even when the stent edge or covered membrane overlaps a bifurcation. However, the same holes that permit branch drainage and tissue anchoring may allow tumor or hyperplastic tissue to grow into the stent. Indeed, ingrowth has been reported after MHSEMS placement for distal malignant biliary obstruction [8], and another comparative study in pancreatic cancer found a shorter time to RBO with MHSEMSs than with conventional FCMSs [9]. Reduced migration therefore does not necessarily translate into superior overall patency or easier late removal.

The ideal strategy for MHBO should therefore balance four longitudinal objectives: durable drainage, preservation of segmental bile flow, technical feasibility of multisegmental deployment, and the ability to revise or remove the stent when the clinical course changes. Conventional UMSs prioritize patency and branch preservation but sacrifice removability; PSs maximize exchangeability but usually at the cost of smaller caliber and more frequent reintervention; conventional FCMSs combine larger caliber with removability but may occlude branches or migrate; and MHSEMSs represent a rational attempt to reconcile these competing properties, although their benefits and trade-offs still require clinical validation. Future trials should compare these strategies using not only time to RBO but also successful removal at prespecified dwell periods, segment-specific adverse events, success of selective reintervention, cumulative number and duration of procedures, unplanned hospitalization, compatibility with subsequent surgery, and patient-reported burden. The next advance in MHBO drainage may depend less on whether a stent is simply covered or uncovered—or even removable or non-removable—than on how well the initial drainage plan anticipates the patient's likely oncological trajectory and preserves options for what comes next.

Hirofumi Kogure: conceptualization; literature review; writing – original draft; writing – review and editing. The author approved the final version of the manuscript.

The author has nothing to report.

The author declares no conflicts of interest.

This article is linked with T. Inoue et al. To view this article visit https://doi.org/10.1111/den.70031.

Data sharing not applicable to this article as no datasets were generated or analysed during the current study.

超越可移除性:多孔覆盖金属支架能否克服恶性肝门胆道梗阻的剩余挑战?
恶性肝门胆道梗阻(MHBO)仍然是胰胆道内镜治疗中技术要求最高的条件之一。尽管使用未覆盖的自膨胀金属支架(UMSs)进行双侧引流通常受到青睐,因为其延长了通畅时间并保留了侧支引流,但UMSs的不可移除性代表了一个越来越重要的限制。全身治疗的改善延长了胆道和其他恶性肿瘤患者的生存期,因此放置UMS后复发性胆道梗阻(RBO)更常见。一旦由于肿瘤向内生长或组织增生导致UMS嵌入胆管壁,通常不可能切除,必须通过或沿现有支架进行再次干预。这可能会限制对未引流或新阻塞段的选择性进入,增加重复手术的复杂性,并留下永久性金属框架,可能会阻碍后续引流策略的修改或使转换手术复杂化。从这个意义上说,可移除性不仅仅是技术上的便利:它保留了在再次介入手术时重置胆道解剖结构的选择。最近,在一项多中心回顾性研究中,Inoue等人比较了在不可切除的MHBO中,采用6毫米超薄全覆盖金属支架(fcms)与传统的UMS部署的冠状上支架-支架部署。倾向评分匹配后,每组52例。技术和临床成功率相当,而FCMS组的RBO发生率明显低于UMS组(32.0%对60.8%),RBO时间明显更长。重要的是,所有接受再干预的患者都可以切除fcms。fcms组的再干预时间更短,再干预总次数和需要多次再干预的患者比例均较低。这些发现很重要,因为它们不仅将可拆卸性与装置检索联系起来,而且还与纵向胆道管理的累积负担联系起来。因此,该研究提出了一个更广泛的问题:MHBO引流应该主要追求“永久引流”,以零再干预为理想目标,还是“可移动引流”,接受可能发生的再干预,但寻求使其可预测和技术上的直接性?这些目标不应被视为相互排斥或设备之间的竞争。相反,它们代表了患者预期临床过程中的不同优先级。对于预期寿命有限或手术风险高的患者,以尽可能低的可能性进行持久引流可能是主要目标。相比之下,对于那些希望接受长期全身治疗的患者,那些可能需要反复干预的患者,或者那些转换手术仍然有现实可能性的患者,可移除性可能特别有价值。因此,目标应该从确定一种普遍优越的支架转向选择一种引流策略,在保留与个体患者最相关的未来选择的同时,保持足够的通畅。这一观点也阐明了塑料支架(ps)和可拆卸金属支架之间的区别。导管内PSs可以选择性地交换或移除,MHBO患者具有可靠的移除性。它们的小口径和相对较低的径向力可以减少分支覆盖的后果,使顺序重建相对简单;然而,它们更容易堵塞,通常需要更频繁的计划或按需交换。相比之下,可移动fcms提供更大的管腔直径,并且在MHBO患者中显示出比ps更长的支架通畅。代价是fcms施加更大的径向力,它们的覆盖会阻塞侧分支;移位、支架末端过度生长和组织反应也会使后续的移除手术复杂化。因此,“可拆卸”并不是PSs和fcms共同拥有的双重特性:PSs倾向于交换的便利性和可重复性,而fcms则寻求将可拆卸性与金属支架的口径和耐用性结合起来。那么,是什么决定了良好的可移除性呢?首先,覆盖层必须保持机械完整性和足够的不渗透性,以防止肿瘤或增生组织将支架固定在管壁上。因此,覆盖材料和建筑是核心,尽管针对MHBO的比较证据仍然有限。其次,支架应具有足够的径向力和锚定力以抵抗迁移,而不会在未覆盖的末端或锚定元件处产生过度的组织反应。支架直径可能会影响这种平衡:纤细的FCMS可以促进在门部部署多个支架,但仅靠直径不能保证可移除性。 第三,近端和远端定位很重要,因为即使支架体完全覆盖,分叉处或反应性组织内暴露的边缘也可能难以恢复。最后,留置时间可能是相关的。来自非恶性胆道狭窄的数据表明,延长停留时间可通过增生性过度生长[4]增加FCMS移除失败,尽管这种影响在恶性肝门疾病中的程度尚不清楚。考虑到这些因素,评估可移除性应该作为一个与时间相关的终点——在临床相关的停留期后成功的无创性拔出——而不是作为支架部署时的固有标签。在乳头上放置可进一步改善纤细fcms的性能。避免支架腔直接暴露于十二指肠内容物可减少十二指肠胆汁反流和污泥形成,而乳头上位置可减少远端向十二指肠的迁移。然而,Inoue的研究也表明,可移除性并不能消除覆盖肝门胆道树的固有缺点。FCMS组2例患者在2个月内出现后节段胆囊瘤,需要移除支架。在这两种情况下,右侧FCMS的近端位于前后部门导管的分叉处。虽然没有明确的梗阻,但强烈怀疑后分支覆盖或局部胆汁流动紊乱。因此,覆盖支架的近端可能与狭窄本身一样重要。支闭塞不仅可以表现为显性胆管炎,还可以表现为节段性胆管炎、肝脓肿或胆囊瘤。这些事件可能难以预测,因为显然在手术结束时充分的造影剂引流并不一定保证支架完全扩张后持续引流。将支架近端精确地放置在主要分叉处可能特别危险。当前后分支导管均通畅时,完全桥接分支或使用三个支架单独引流可能比在分支处保留覆盖的支架边缘更可取。因此,术前评估靶肝体积和详细解释三维胆道解剖是必要的。当预期延长生存期时,保留节段引流尤为重要,因为一个小的分支相关问题在临床上可能在几周内可以忍受,但在几个月的全身治疗后可能会产生严重后果。在Inoue研究中观察到的传统细长fcms与分支相关的不良事件为进一步的支架设计提供了假设,而不是多孔全覆盖自膨胀金属支架(MHSEMSs)本身的证据。Inoue等人没有评价MHSEMSs。然而,从概念上讲,MHSEMSs将多个小孔纳入覆盖膜,目的是允许胆汁从邻近分支流动,同时保留覆盖支架的许多优点。这些孔也可以允许有限的组织锚定,从而减少迁移。已有报道成功地将MHSEMSs置于支架内和并排部署于MHBO,证明了技术可行性,同时保持了潜在的可移除性[5,6]。最近的一项猪肝门梗阻模型也表明,植入MHSEMS后,保留了侧支引流和成功的可移除性。这些观察结果使多孔概念具有吸引力,但其在MHBO中的临床价值仍有待进一步验证。恶性远端胆道梗阻的临床数据提供了进一步的概念证明,同时也说明了设计的权衡。在一项111例患者的多中心回顾性研究中,植入MHSEMS后的迁移率仅为1.9%,88.9%的尝试病例成功移除。这些发现表明,多孔设计可能解决两个重要的fcms相关问题:侧分支阻塞和迁移。在门静脉设置中,即使支架边缘或覆盖膜与分支重叠,通过孔的通信也可能保持部门导管的引流。然而,允许分支引流和组织锚定的相同孔可能允许肿瘤或增生性组织生长到支架中。事实上,有报道称,在远端恶性胆道梗阻[8]放置MHSEMSs后,肿瘤长入,另一项胰腺癌的比较研究发现,与传统的FCMSs[9]相比,MHSEMSs的RBO时间更短。因此,减少的移位不一定转化为更好的整体通畅或更容易的晚期切除。 因此,MHBO的理想策略应该平衡四个纵向目标:持久引流、保留节段胆汁流动、多节段部署的技术可行性,以及当临床病程改变时修改或移除支架的能力。传统的ums优先考虑开放性和分支保留,但牺牲了可移除性;psi最大限度地提高了互换性,但通常以较小的口径和更频繁的再干预为代价;传统的fcms结合了更大的口径和可移除性,但可能会阻塞分支或迁移;MHSEMSs代表了一种合理的尝试来调和这些相互竞争的特性,尽管它们的益处和权衡仍然需要临床验证。未来的试验应该比较这些策略,不仅要考虑到RBO的时间,还要考虑在预定的停留时间内成功切除,特定节段的不良事件,选择性再干预的成功,手术的累积次数和持续时间,计划外住院,与后续手术的兼容性,以及患者报告的负担。MHBO引流的下一个进展可能不太取决于支架是简单地覆盖还是不覆盖,甚至是可移动还是不可移动,而是取决于最初的引流计划对患者可能的肿瘤轨迹的预测程度,并为下一步的治疗保留选择。小木博文:概念化;文献综述;写作——原稿;写作——审阅和编辑。作者批准了手稿的最终定稿。作者没有什么可报道的。作者声明无利益冲突。这篇文章与T. Inoue等人有关。要查看这篇文章,请访问https://doi.org/10.1111/den.70031.Data分享不适用于这篇文章,因为在目前的研究中没有生成或分析数据集。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Digestive Endoscopy
Digestive Endoscopy 医学-外科
CiteScore
10.10
自引率
15.10%
发文量
291
审稿时长
6-12 weeks
期刊介绍: Digestive Endoscopy (DEN) is the official journal of the Japan Gastroenterological Endoscopy Society, the Asian Pacific Society for Digestive Endoscopy and the World Endoscopy Organization. Digestive Endoscopy serves as a medium for presenting original articles that offer significant contributions to knowledge in the broad field of endoscopy. The Journal also includes Reviews, Original Articles, How I Do It, Case Reports (only of exceptional interest and novelty are accepted), Letters, Techniques and Images, abstracts and news items that may be of interest to endoscopists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书